98%
921
2 minutes
20
The coordination sphere of the Fe(II) terpyridine complex 1 is rigidified by fourfold interlinking of both terpyridine ligands. Profiting from an octa-aldehyde precursor complex, the ideal dimensions of the interlinking structures are determined by reversible Schiff-base formation, before irreversible Wittig olefination provided the rigidified complex. Reversed-phase HPLC enables the isolation of the all-trans isomer of the Fe(II) terpyridine complex 1, which is fully characterized. While temperature independent low-spin states were recorded with superconducting quantum interference device (SQUID) measurements for both, the open precursor 8 and the interlinked complex 1, evidence of the increased rigidity of the ligand sphere in 1 was provided by proton T relaxation NMR experiments. The ligand sphere fixation in the macrocyclized complex 1 even reaches a level resisting substantial deformation upon deposition on an Au(111) surface, as demonstrated by its pristine form in a low temperature ultra-high vacuum scanning tunneling microscope experiment.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7540000 | PMC |
http://dx.doi.org/10.1002/anie.202006340 | DOI Listing |
Angew Chem Int Ed Engl
September 2020
Department of Chemistry, University of Basel, St. Johanns-Ring 19, 4056, Basel, Switzerland.
The coordination sphere of the Fe(II) terpyridine complex 1 is rigidified by fourfold interlinking of both terpyridine ligands. Profiting from an octa-aldehyde precursor complex, the ideal dimensions of the interlinking structures are determined by reversible Schiff-base formation, before irreversible Wittig olefination provided the rigidified complex. Reversed-phase HPLC enables the isolation of the all-trans isomer of the Fe(II) terpyridine complex 1, which is fully characterized.
View Article and Find Full Text PDFWe propose a new method for generating synthetic CT images from modified Dixon (mDixon) MR data. The synthetic CT is used for attenuation correction (AC) when reconstructing PET data on abdomen and pelvis. While MR does not intrinsically contain any information about photon attenuation, AC is needed in PET/MR systems in order to be quantitatively accurate and to meet qualification standards required for use in many multi-center trials.
View Article and Find Full Text PDFKnowl Based Syst
August 2017
Case Center for Imaging Research, Case Western Reserve University, Cleveland, Ohio, USA.
We study a novel fuzzy clustering method to improve the segmentation performance on the target texture image by leveraging the knowledge from a prior texture image. Two knowledge transfer mechanisms, i.e.
View Article and Find Full Text PDF