Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: Detection of epidermal growth factor receptor (EGFR) mutations in exons 18-21 is recommended in all patients with advanced Non-small-cell lung carcinoma due to the demonstrated efficiency of the standard therapy with tyrosine kinase inhibitors in EGFR-mutated patients. Therefore, choosing a suitable technique to test EGFR mutational status is crucial to warrant a valid result in a short turnaround time using the lowest possible amount of tissue material. The Idylla™ EGFR Mutation Test is a simple, fast and reliable method designed for the detection of EGFR mutations from formalin-fixed paraffin-embedded samples. The aim of this study was the Clinical Performace Evaluation of the Idylla™ EGFR Mutation Test on the Idylla™ System.
Methods: EGFR mutational status was determined on 132 archived formalin-fixed paraffin-embedded tissue sections with Idylla™ technology. Results were compared with the results previously obtained by routine method in the reference lab (Therascreen® EGFR RGQ PCR v2, Qiagen in Molecular Pathology lab, Hospital Universitario Virgen del Rocío de Sevilla).
Results: The overall agreement between results obtained with the Idylla™ EGFR Mutation Test and the Comparator test method was 95.38% (with 1-sided 95% lower limit of 91.7%) showing Positive Diagnostic Agreement of 93.22% and Negative Diagnostic Agreement of 97.18%, with a Limit Of Detection ≤5%.
Conclusions: The Idylla™ EGFR Mutation Test passed its clinical validity performance characteristics for accuracy.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7126408 | PMC |
http://dx.doi.org/10.1186/s12885-020-6697-7 | DOI Listing |