A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Near point-of-care, point-mutation test to detect drug resistance in HIV-1: a validation study in a Mexican cohort. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: Pretreatment HIV-drug resistance (PDR, HIVDR) to non-nucleoside reverse transcriptase inhibitors (NNRTIs) is increasing globally. NNRTIs continue to be used as first-line antiretroviral therapy (ART) in some communities due to the cost of dolutegravir-based ART or dolutegravir-associated adverse events. A simplified version of the oligonucleotide ligation assay (OLA) - 'OLA-Simple' - is a low-cost, near point-of-care assay that provides ready-to-use lyophilized reagents and reports HIVDR mutations as colored lines on lateral flow strips. Our objective was to design and validate OLA-Simple for a Mexican cohort.

Design: OLA-Simple probes to detect K65R, K103N/S, Y181C, M184V, and G190A were optimized for HIV Mexican sequences. Sixty clinical plasma specimens were analyzed by OLA-Simple by technicians blinded to Illumina-MiSeq sequences, and HIVDR results were compared.

Methods: Plasma RNA was tested using OLA-Simple kits. OLA-Simple lateral flow strips were read by in-house software, and were classified as mutant or wild-type at each codon. The comparison of results by OLA-Simple and Miseq was used to generate receiver-operating characteristic curves.

Results: OLA-Simple PCR amplified 59 of 60 specimens and successfully genotyped 287 of 295 codons, with eight of 295 (2.7%) indeterminate results. Compared to MiSeq, OLA-Simple gave five of 295 (1.7%) false-positive and four of 295 (1.4%) false-negative results. Excluding indeterminate results, OLA-Simple classified mutant with an accuracy of 97.4 and 98.8% when using thresholds at 10 and 25% mutant within an individual's HIV quasispecies, respectively.

Conclusions: Compared to MiSeq, OLA-Simple detected HIVDR with high sensitivity and accuracy. OLA-Simple could expand access to affordable and rapid HIVDR testing to guide appropriate ART choices in populations using NNRTI-based ART.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8284934PMC
http://dx.doi.org/10.1097/QAD.0000000000002524DOI Listing

Publication Analysis

Top Keywords

ola-simple
11
lateral flow
8
flow strips
8
classified mutant
8
compared miseq
8
miseq ola-simple
8
hivdr
5
point-of-care point-mutation
4
point-mutation test
4
test detect
4

Similar Publications