Nucleic acid amplification tests (NAATs) can achieve high accuracy for diagnosing infectious diseases by targeting conserved genetic sequences specific to the target organism. Isothermal NAATs, such as reverse-transcription loop mediated isothermal amplification (RT-LAMP), simplify instrumentation requirements, facilitating point-of-care testing. However, sequence variation due to genetic variability can cause false negative results.
View Article and Find Full Text PDFThe WHO currently recommends dolutegravir (DTG)-based ART for persons living with HIV infection in resource-limited-settings (RLS). To expand access to testing for HIV drug resistance (DR) to DTG in RLS, we developed probes for use in the oligonucleotide ligation assay (OLA)-Simple, a near-point of care HIV DR kit. Genotypic data from clinical trials and case reports were used to determine the mutations in HIV-1 integrase critical to identifying individuals with DTG-resistance at virologic failure of DTG-based ART.
View Article and Find Full Text PDFPathogens encapsulate or encode their own suite of enzymes to facilitate replication in the host. The pathogen-derived enzymes possess specialized activities that are essential for pathogen replication and have naturally been candidates for drug targets. Phenotypic assays detecting the activities of pathogen-derived enzymes and characterizing their inhibition under drugs offer an opportunity for pathogen detection, drug resistance testing for individual patients, and as a research tool for new drug development.
View Article and Find Full Text PDFBackground & Aims: Alcohol-associated liver diseases (ALDs) and alcohol use disorder (AUD) pose a global health risk. AUD is underrecognized in the elderly, and the burden of AUD complications, including ALD, may increase with aging populations and rising alcohol intake. However, there is a lack of epidemiological evidence on AUD and ALD in the elderly.
View Article and Find Full Text PDFSince SARS-CoV-2 is a highly transmissible virus, a rapid and accurate diagnostic method is necessary to prevent virus spread. We aimed to develop and evaluate a new rapid colorimetric reverse transcription loop--mediated isothermal amplification (RT-LAMP) assay for SARS-CoV-2 detection in a single closed tube. Nasopharyngeal and throat swabs collected from at-risk individuals testing for SARS-CoV-2 were used to assess the sensitivity and specificity of a new RT-LAMP assay against a commercial qRT-PCR assay.
View Article and Find Full Text PDFLateral flow assays (LFAs) provide a simple and quick option for diagnosis and are widely adopted for point-of-care or at-home tests. However, their sensitivity is often limited. Most LFAs only allow 50 μL samples while various sample types such as saliva could be collected in much larger volumes.
View Article and Find Full Text PDFIntroduction Early-onset colorectal cancer (EOCRC) is becoming a growing concern due to its increased incidence among younger individuals, particularly in areas with limited healthcare access and funding, such as in countries with a low sociodemographic index (SDI). However, there are limited studies regarding this problem. Therefore, our study primarily aims to address the dearth of knowledge in this area by assessing the trends in EOCRC in low SDI countries over 10 years.
View Article and Find Full Text PDFPLOS Glob Public Health
February 2022
Usability is an overlooked aspect of implementing lab-based assays, particularly novel assays in low-resource-settings. Esoteric instructions can lead to irreproducible test results and patient harm. To address these issues, we developed a software application based on "Aquarium", a laboratory-operating system run on a computer tablet that provides step-by-step digital interactive instructions, protocol management, and sample tracking.
View Article and Find Full Text PDFObjectives: Assess the impact of pre-treatment high-frequency and low-frequency drug-resistant HIV variants on long-term outcomes of first-line efavirenz-based antiretroviral therapy (ART).
Design: Prospective observational study.
Methods: Participants' pre-treatment plasma RNA had two sections of HIV pol encoding reverse transcriptase sequenced (Illumina, MiSeq) using unique molecular identifiers to detect wild-type (pre-treatment drug-resistant variants less than 1% of viral quasispecies), low-frequency (1-9%) or high-frequency drug-resistant variants (10-100%).
The COVID-19 pandemic interrupted routine care for individuals living with HIV, putting them at risk of virologic failure and HIV-associated illness. Often this population is at high risk for exposure to SARS-CoV-2 infection, and once infected, for severe disease. Therefore, close monitoring of HIV plasma viral load (VL) and screening for SARS-CoV-2 infection are needed.
View Article and Find Full Text PDFThe increasing prevalence of variant lineages during the COVID-19 pandemic has the potential to disrupt molecular diagnostics due to mismatches between primers and variant templates. Point-of-care molecular diagnostics, which often lack the complete functionality of their high-throughput laboratory counterparts, are particularly susceptible to this type of disruption, which can result in false-negative results. To address this challenge, we have developed a robust Loop Mediated Isothermal Amplification assay with single tube multiplexed multitarget redundancy and an internal amplification control.
View Article and Find Full Text PDFThe COVID-19 pandemic is among the greatest health and socioeconomic crises in recent history. Although COVID-19 vaccines are being distributed, there remains a need for rapid testing to limit viral spread from infected individuals. We previously identified the SARS-CoV-2 spike protein N-terminal domain (NTD) binding DNA aptamer 1 (SNAP1) for detection of SARS-CoV-2 virus by aptamer-antibody sandwich enzyme-linked immunoassay (ELISA) and lateral flow assay (LFA).
View Article and Find Full Text PDFNew variants of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) continue to arise and prolong the coronavirus disease 2019 (COVID-19) pandemic. Here, we used a cell-free expression workflow to rapidly screen and optimize constructs containing multiple computationally designed miniprotein inhibitors of SARS-CoV-2. We found the broadest efficacy was achieved with a homotrimeric version of the 75-residue angiotensin-converting enzyme 2 (ACE2) mimic AHB2 (TRI2-2) designed to geometrically match the trimeric spike architecture.
View Article and Find Full Text PDFAffordably tracking the transmission of respiratory infectious diseases in urban transport infrastructures can inform individuals about potential exposure to diseases and guide public policymakers to prepare timely responses based on geographical transmission in different areas in the city. Towards that end, we designed and tested a method to detect SARS-CoV-2 RNA in the air filters of public buses, revealing that air filters could be used as passive fabric sensors for the detection of viral presence. We placed and retrieved filters in the existing HVAC systems of public buses to test for the presence of trapped SARS-CoV-2 RNA using phenol-chloroform extraction and RT-qPCR.
View Article and Find Full Text PDFPoint-of-care diagnostics often use isothermal nucleic acid amplification for qualitative detection of pathogens in low-resource healthcare settings but lack sufficient precision for quantitative applications such as HIV viral load monitoring. Although viral load (VL) monitoring is an essential component of HIV treatment, commercially available tests rely on relatively high-resource chemistries like real-time polymerase chain reaction and are thus used on an infrequent basis for millions of people living with HIV in low-income countries. To address the constraints of low-resource settings on nucleic acid quantification, we describe a recombinase polymerase amplification and lateral flow detection approach that quantifies HIV-1 DNA or RNA by comparison to a competitive internal amplification control (IAC) of a known copy number, which may be set to any useful threshold (in our case, a clinically relevant threshold for HIV treatment failure).
View Article and Find Full Text PDFRNA amplification tests sensitively detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection, but their complexity and cost are prohibitive for expanding coronavirus disease 2019 (COVID-19) testing. We developed “Harmony COVID-19,” a point-of-care test using inexpensive consumables, ready-to-use reagents, and a simple device. Our ready-to-use, multiplexed reverse transcription, loop-mediated isothermal amplification (RT-LAMP) can detect down to 0.
View Article and Find Full Text PDFAIDS Res Hum Retroviruses
December 2021
The nucleoside reverse transcriptase inhibitor abacavir (ABC) is used commonly to treat young children with HIV infection and is a component of the fixed-dose-combination Triumeq. ABC can trigger a severe hypersensitivity reaction in people who are homozygous or heterozygous for . Testing for before ABC initiation is standard-of-care in high-resource settings, but current tests are costly or difficult to access in resource-limited settings.
View Article and Find Full Text PDFBackground: COVID-19 pandemic interrupted routine care for individuals living with HIV, putting them at risk of becoming virologically unsuppressed and ill. Often they are at high risk for exposure to SARS-CoV-2 infection and severe disease once infected. For this population, it is urgent to closely monitor HIV plasma viral load ( ) and screen for SARS-COV-2 infection.
View Article and Find Full Text PDFThe increasing prevalence of variant lineages during the COVID-19 pandemic has the potential to disrupt molecular diagnostics due to mismatches between primers and variant templates. Point-of-care molecular diagnostics, which often lack the complete functionality of their high throughput laboratory counterparts, are particularly susceptible to this type of disruption, which can result in false negative results. To address this challenge, we have developed a robust Loop Mediated Isothermal Amplification assay with single tube multiplexed multi-target redundancy and an internal amplification control.
View Article and Find Full Text PDF