Objective: A 24-hour urine nor/metanephrine (urine NM-MN) measurements are a recommended first step in pheochromocytoma diagnosis. We hypothesized the presence of renal impairment (CKD) significantly confounds the results obtained in a urine NM-MN collection, giving artificially lower measurements.

Design: Retrospective review of a comprehensive laboratory database with all urine NM-MN results from Southern Alberta from 2010 to 2018 (n = 15 505). After excluding high probability pheochromocytoma cases, results from patients with three levels of CKD (n = 796) were compared to those without CKD to determine the potential CKD effect.

Patients: All patients having urine NM-MN collection during the time period, irrespective of ordering physician or test indication.

Measurements: Urine NM-MN was measured by liquid chromatography-tandem mass spectrometry and glomerular filtration rate determined within a median of 1.9 days, as estimated by CKD-EPI equation.

Results: In subjects with mild-to-moderate renal impairment, there was no continuous gradient between subnormal renal function and urine NM-MN measures. When the estimated GFR was < 15 mL/min/m , the hypothesized effect on lowered urine NM-MN became apparent.

Conclusions: A 24-hour urine NM-MN measurement is unlikely to be affected by mild-to-moderate renal impairment and may be used as a reliable diagnostic test. With more advanced renal impairment, CKD-specific reference ranges or an alternative test may be needed.

Download full-text PDF

Source
http://dx.doi.org/10.1111/cen.14180DOI Listing

Publication Analysis

Top Keywords

urine nm-mn
24
renal impairment
12
urine
8
24-hour urine
8
nm-mn collection
8
nm-mn
6
moderate renal
4
impairment preclude
4
preclude accuracy
4
accuracy 24-hour
4

Similar Publications

In welding, there is a potential risk due to metal-oxide nanoparticles (MONPs) exposure of workers. To investigate this possibility, the diameter and number particles concentration of MONPs were evaluated in different biological matrices and in personal air samples collected from 18 stainless-steel welders and 15 unexposed administrative employees engaged in two Italian mechanical engineering Companies. Exhaled breath condensate (EBC) and urine were sampled at pre-shift on 1st day and post-shift on 5th day of the workweek, while plasma and inhalable particulate matter (IPM) at post-shift on 5th day and analysed using the Single Particle Mass Spectrometry (SP-ICP-MS) technique to assess possible exposure to CrO, MnO and NiO nanoparticles (NPs) in welders.

View Article and Find Full Text PDF

Objective: A 24-hour urine nor/metanephrine (urine NM-MN) measurements are a recommended first step in pheochromocytoma diagnosis. We hypothesized the presence of renal impairment (CKD) significantly confounds the results obtained in a urine NM-MN collection, giving artificially lower measurements.

Design: Retrospective review of a comprehensive laboratory database with all urine NM-MN results from Southern Alberta from 2010 to 2018 (n = 15 505).

View Article and Find Full Text PDF