Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: To evaluate accelerated multi-contrast volumetric imaging with isotropic resolution reconstructed using low-rank and spatially varying edge-preserving constrained compressed sensing parallel imaging reconstruction (CP-LASER), for assessing infarct heterogeneity on post-infarction patients as a precursor to studies of utility for predicting ventricular arrhythmias.
Methods: Eleven patients with prior myocardial infarction were included in the study. All subjects underwent cardiovascular magnetic resonance (CMR) scans including conventional two-dimensional late gadolinium enhancement (2D LGE) and three-dimensional multi-contrast late enhancement (3D MCLE) post-contrast. The extent of the infarct core and peri-infarct gray zone of a limited mid-ventricular slab were derived respectively by analyzing MCLE images with an isotropic resolution of 2.2 mm and an anisotropic resolution of mm , and LGE images with a resolution of mm ; the respective measures across all subjects were statistically compared.
Results: Using 3D MCLE, the infarct core size measured with isotropic resolution was similar to that measured with anisotropic resolution, while the peri-infarct gray zone size measured with isotropic resolution was smaller than that measured with anisotropic resolution ( , Cohen's ). Isotropic 3D MCLE yielded a significantly smaller measure of the peri-infarct gray zone size than conventional 2D LGE ( , Cohen's ). Overall, we have successfully shown the utility of isotropic 3D MCLE in a pilot patient study. Our results suggest that smaller voxels lead to more accurate differentiation between isotropic 3D MCLE-derived gray zone and core infarct because of diminished partial volume effect.
Conclusion: The CP-LASER accelerated 3D MCLE with isotropic resolution can be used in patients and yields excellent delineation of infarct and peri-infarct gray zone characteristics.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/nbm.4253 | DOI Listing |