98%
921
2 minutes
20
Retention time shifts in second-order calibration-assisted chromatographic analysis seriously impact the modeling and quantitative accuracies in complex systems. In this work, three second-order methods, i.e. alternating trilinear decomposition (ATLD) algorithm, multivariate curve resolution-alternating least squares (MCR-ALS), alternating trilinear decomposition-assisted multivariate curve resolution (ATLD-MCR), were compared their performance to process liquid chromatographic data in the presence of retention time shifts and overlapped peaks. Firstly, the validation samples contain five tea polyphenols at three concentrate levels within the calibration ranges, helped to understand, visualize and interpret these features of three second-order multivariate methods. Secondly, experimental data were studied concerning the determination of polyphenols in Chinese tea samples by HPLC-DAD. The results showed that all three second-order multivariate methods realized satisfactory quantification for five targeted analytes in Pu-Er ripe tea samples and Green tea samples even with the interference of slight retention time shifts, average recoveries were 91.23% -113.16% for ATLD, 89.96%-115.96% for ATLD-MCR, 90.64%-117.60% for MCR-ALS, respectively. However, ATLD was disappointing in the case of larger time shifts (approx. 4.00 s and 6.40 s) occurring for the quantitative analysis of Black tea and Clinacanthus nutans tea, the average recoveries were just 67.33-84.05%. Relatively, MCR-ALS and ATLD-MCR were more significantly excellent, satisfactory results still can be obtained, the average recoveries for MCR-ALS and ATLD-MCR were in the range of 86.04-117.60% and 89.96-115.96%, respectively.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2020.460905 | DOI Listing |
Environ Sci Pollut Res Int
September 2025
Department of Dyes and Chemical Engineering, Bangladesh University of Textiles, Dhaka, Bangladesh.
This study quantitatively evaluated the adsorption performance of natural bentonite for removing three dye classes-cationic (Basic dye: BEZACRYL RED GRL), anionic (Reactive dye: AVITERA LIGHT RED SE), and non-ionic (Disperse dye: BEMACRON BLUE HP3R) from synthetic textile wastewater. Batch adsorption experiments were conducted under varying conditions of contact time (15-90 min), adsorbent dosage (20-60 g L⁻), pH (4 and 12), and temperature (25-100 °C), with dye concentrations quantified by UV-Vis spectroscopy. At a contact time of 30 min and room temperature (25 °C), maximum removal efficiencies reached 99.
View Article and Find Full Text PDFVestn Oftalmol
September 2025
OOO Diagnosticheskij tsentr Zreniye, Saint Petersburg, Russia.
Objective: This study evaluated the effect of sequential therapy with different dosages of Mexidol on the stabilization of glaucomatous optic neuropathy (GON) in patients with primary open-angle glaucoma (POAG).
Material And Methods: The study included 80 patients (160 eyes) with stage II and III POAG, randomized into three groups comparable by age, gender, and distribution of glaucoma stage. All patients received sequential therapy with Mexidol (14 days parenterally followed by 90 days orally).
ACS Omega
September 2025
Departamento de Física y Química Teórica, Facultad de Química, Universidad Nacional Autónoma de México, Cd. Universitaria, 04510 Ciudad de Mexico, Mexico.
In this study, we introduce a set of novel computational strategies based on second-order Mo̷ller-Plesset perturbation theory (MP2), enhanced through acceleration techniques, such as the resolution of the identity (RI). These approaches are further refined via spin-component scaling (SCS), following Grimme's methodology, and are specifically calibrated for the quantitatively accurate prediction of weak interaction energiesinteractions that play a critical role in biological systems. Among the developed methods, three variants exhibit outstanding performance, surpassing the accuracy of several state-of-the-art, nondynamical electronic structure techniques.
View Article and Find Full Text PDFNanoscale Horiz
September 2025
Theoretical Chemical Physics Group, Research Institute for Materials Science and Engineering, University of Mons, 20 Place du Parc, Mons B-7000, Belgium.
Two-photon spontaneous emission (TPSE) is a second-order quantum process with promising applications in quantum optics that remains largely unexplored in molecular systems, which are usually very inefficient emitters. In this work, we model the first molecular two-photon emitters and establish the design rules, highlighting their differences from those governing two-photon absorbers. Using both time-dependent density functional theory and Pariser-Parr-Pople calculations, we calculate TPSE in three π-conjugated molecules and identify a dominant pathway.
View Article and Find Full Text PDFAnal Chim Acta
November 2025
The Associated Laboratory for Green Chemistry (LAQV) of the Network of Chemistry and Technology (REQUIMTE) - the Portuguese Research Centre for Sustainable Chemistry, Department of Chemical Sciences, Faculty of Pharmacy, University of Porto, 4050-313, Porto, Portugal. Electronic address:
Background: When using semiconductor quantum dots (QDs) for single-analyte sensing, recognition is commonly achieved through interactions with capping ligands attached to the QDs surface. These ligands form an organic layer that provides stability in solution and assures selectivity by binding the target analyte via surface functional groups. However, a common analytical challenge arises in the subsequent stage of the QD-based sensing scheme.
View Article and Find Full Text PDF