A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

HPLC-MS/MS method for the simultaneous quantification of dolutegravir, elvitegravir, rilpivirine, darunavir, ritonavir, raltegravir and raltegravir-β-d-glucuronide in human plasma. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Therapeutic drug monitoring (TDM) is essential in the optimization of antiretroviral (ARV) treatments. In this work, we describe a new method for the simultaneous quantification of six molecules: the three novel ARV agents dolutegravir (DTG), elvitegravir (ELV) and rilpivirine (RPV), the first integrase inhibitor raltegravir (RAL) and its major metabolite the raltegravir-β-d-glucuronide (RAL-GLU), an protease inhibitor darunavir (DRV) and its booster ritonavir (RTV) in human plasma. The drugs were extracted from 100 μL of plasma by a simple method of protein precipitation using acetonitrile. The separation was carried out on a Kinetex phehyl-hexyl column using a phase mobile composed of 55 % of water (0.05 % formic acid,v/v) and 45 % of methanol (0.05 % formic acid,v/v). The flow rate was set at 0.5 mL/min. The calibration ranged from 60 to 15000 ng/mL for DRV, from 20 to 5000 ng/mL for DTG and ELV, from 10 to 2500 ng/mL for RAL, RAL-GLU, RTV and RPV. The proposed method was validated with a good precision (inter- and intra-day CV% inferior to 12.3 %) and a good accuracy (inter- and intra-day bias between -9.9 % and 10 %) for all the analytes. The proposed method is simple, reliable and suitable for therapeutic drug monitoring (TDM) and for pharmacokinetics studies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2020.113119DOI Listing

Publication Analysis

Top Keywords

method simultaneous
8
simultaneous quantification
8
human plasma
8
therapeutic drug
8
drug monitoring
8
monitoring tdm
8
005 formic
8
formic acidv/v
8
proposed method
8
inter- intra-day
8

Similar Publications