98%
921
2 minutes
20
Modular hip stems offer many advantages in revision arthroplasty. However, the region of modularity is prone to failure. Fracture of the non-cemented fluted tapered titanium Modular Prosthesis (MP) stem is relatively rare. We present here a case of a distal non-traumatic fracture of the MP stem and review the previously reported cases. A 53-years old, relatively active, male patient with a body mass index (BMI) of 37 kg/m had a fracture of the non-cemented MP stem on the left side after five years without complaints. The BMI was 45 at the time of implantation of the MP stem. His weight was significantly reduced, but the stem failed and fractured at an atypical site, quite distal to the modular junction. The broken stem with a relatively small diameter had been exchanged to a larger one. Fracture of the non-cemented fluted proximally-modular distally-tapered titanium MP stem might occur after years. Even in cases of good bone quality of the proximal femur, patient BMI and activity level should be considered when selecting the stem diameter. Furthermore, proximal bone loss of the femur should be considered as a potential cause of failure.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6985004 | PMC |
http://dx.doi.org/10.1016/j.jcot.2019.07.020 | DOI Listing |
Neuroradiology
September 2025
Department of Neuroradiology, Pitié-Salpêtrière Hospital, Paris, France.
Objective: Evaluating long-term outcomes following cementoplasty in patients with multiple myeloma (MM).
Methods: This is a single-center, retrospective study on all cementoplasties performed between January 2012 and December 2017. Patients with MM with a control MRI or CT scan beyond 5 years after the procedure were included.
Brain Spine
February 2025
Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Liebigstrasse 20, 04103, Leipzig, Germany.
Background: Although cement augmentation of pedicle screws increases stability, complications, such as pulmonary embolism, must be considered. One possible approach to minimize complication risk is not augmenting all pedicle screws. It remains unclear whether full augmentation is necessary or if restricted cement augmentation is sufficient regarding cement-associated complications, implant failure, or adjacent fractures.
View Article and Find Full Text PDFIndian J Orthop
May 2025
Hospital for Special Surgery, New York, USA.
Background: Fixation in revision total knee arthroplasty(rTKA) should occur in at least 2 zones(epiphysis, metaphysis, or diaphysis) to maximize fixation strength. We report here the short-term survivorship of unsupported tibial base plates in rTKA when used with a cementless metaphyseal sleeve and non-cemented stem.
Methods: We retrospectively reviewed all patients undergoing rTKA between 2014 and 2021 by a single surgeon at a single institute.
BMC Musculoskelet Disord
April 2025
Department of Bone and Joint Surgery, Renmin Hospital of Wuhan University, Wuhan City, 430060, Hubei Province, China.
Background: In recent years, with the gaining popularity and wide application of total hip arthroplasty (THA), the incidence rate of periprosthetic femoral fractures (PFF) has increased. The treatment of PFF is difficult and has many related complications. Herein, we aimed to construct a nomogram model to predict occurrence of PFF after THA, in order to identify high-risk populations.
View Article and Find Full Text PDFJ Clin Med
February 2025
BG Trauma Center Murnau, 82418 Murnau, Germany.
The German Arthroplasty Registry (EPRD) recorded almost 100,000 femoral neck fractures between 2013 and 2023. The aim of this study was to identify survival rates and risk factors for failure in individuals with femoral neck fractures. A dataset of 97,410 cases from the EPRD was analyzed.
View Article and Find Full Text PDF