Patient-specific instrumentation improves functional kinematics of minimally-invasive total knee replacements as revealed by computerized 3D fluoroscopy.

Comput Methods Programs Biomed

Department of Biomedical Engineering, National Taiwan University, Taipei, Taiwan, R.O.C.; Department of Orthopaedic Surgery, School of Medicine, National Taiwan University, Taipei, Taiwan, R.O.C.. Electronic address:

Published: May 2020


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background And Objectives: Minimally-invasive total knee arthroplasty (MIS-TKA) has demonstrated very good short-term success, but its mid- to long-term results remain inconclusive. The success may be related to the tradeoff between a small incision and accurate positioning of the implant components. Patient-specific instrumentation (PSI) aims to improve the accuracy in restoring the knee axis and the clinical outcomes for MIS-TKA, but the results are yet to be confirmed by accurate assessment during functional activities. The purpose of the current study was to measure and compare the in vivo three-dimensional (3D) rigid-body and surface kinematics of MIS-TKA implanted with and without PSI during isolated knee active flexion/extension and sit-to-stand using state-of-the-art 3D model-based fluoroscopy technology.

Methods: Ten patients treated for advanced medial knee osteoarthritis by MIS-TKA without PSI (non-PSI group) and nine with PSI (PSI group) participated in the current study. Each subject performed non-weight-bearing knee flexion/extension and sit-to-stand tasks while the motion of the prosthetic knee was under bi-plane fluoroscopy surveillance. The computer models of each of the knee prosthesis components were registered to the measured fluoroscopy images for each time frame via a novel validated 3D fluoroscopy method. Non-parametric 1-tailed Mann-Whitney tests were performed to detect the differences in the joint and surface kinematic variables every 10° of knee flexion between the non-PSI and PSI groups. The 1-tailed significance level was at α = 0.05.

Results: The PSI group showed clear, coupled flexion/internal rotation during activities, while the non-PSI group remained roughly at an externally rotated position with slight internal rotations. The coupled rotation in the PSI group was accompanied by an anterior displacement of the medial contact and a posterior displacement of the lateral contact, which was different from the screw-home mechanism. Neither of the two groups showed the normal roll-back phenomenon, i.e., posterior translation of the femur relative to the tibia during knee flexion.

Conclusions: With the state-of-the-art 3D fluoroscopy method, differences in both the rigid-body and surface kinematics of the prosthetic knees between MIS-TKA with and without PSI were identified. Patients with PSI demonstrated significant positive effects on the reconstructed rigid-body kinematics of the knee, showing clearer coupled flexion/internal rotations - an important kinematic characteristic in healthy knees - than those without PSI during activities with or without weight-bearing. However, none of them showed normal contact patterns. The current findings will be helpful for surgical instrument design, as well as for surgical decision-making in MIS total knee arthroplasty.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cmpb.2019.105250DOI Listing

Publication Analysis

Top Keywords

knee
12
total knee
12
psi group
12
psi
11
patient-specific instrumentation
8
minimally-invasive total
8
knee arthroplasty
8
current study
8
rigid-body surface
8
surface kinematics
8

Similar Publications

Objective: Assessment of submarining occurrence in PMHS (Post-Mortem Human Subject) testing can be challenging, particularly for obese PMHS. This study investigates varied kinetic and kinematic response parameters as potential indicators of submarining. Data from 36 whole-body PMHS frontal sled tests conducted under varying boundary conditions were analyzed, incorporating three spring-controlled seat configurations, two extreme anthropometric profiles, two crash pulses, and two seatback angles.

View Article and Find Full Text PDF

Background: Erythema, an early visual indicator of tissue damage preceding pressure injuries (PrIs), presents as redness in light skin tones but is harder to detect in dark skin tones. While thermography shows promise for early PrI detection, validation across different skin tones remains limited. Furthermore, most protocols and models have been developed under highly controlled conditions.

View Article and Find Full Text PDF

Dynamic optimization is a versatile control tool to determine optimal control inputs in a redundantly actuated wearable robot. However, dynamic optimization requires high computational resources for real-time implementation. In this paper, we present a bio-inspired control approach, based on the principle of muscle synergies, to reduce the computational cost of optimization.

View Article and Find Full Text PDF

Objective: To study the electrical conductivity of the knee joints' synovial fluid of human's corpse for assessment of the possibility of its application as criterion of forensic medical diagnosis of postmortem interval.

Material And Methods: The work was carried out on practical forensic medical material on the basis of the Bureau of Forensic Medical Expertise in the Republic of Bashkortostan. During the study, 103 corpses of both sexes, different ages who died from various causes were investigated.

View Article and Find Full Text PDF