This paper reports the development of a stationary phase thickness gradient gas chromatography (GC) column that enables analyte peak focusing and improves separation resolution. Theoretical analysis and simulation demonstrate focusing via a positive thickness gradient, i.e., the stationary phase thickness increases along the column. This effect was experimentally verified by coating a 5 m long capillary column with a film thickness varying from 34 nm at the column inlet to 241 nm at the column outlet. The column was analyzed in forward (thin to thick) and backward (thick to thin) modes and compared to a uniform thickness column with a thickness of 131 nm, using alkanes ranging from C to C and aromatics. Comparison of resolutions between forward mode and the uniform thickness column demonstrated an overall focusing rate (i.e., improvement in peak capacity) of 11.7% on alkanes and 28.2% on aromatics. The focusing effect was also demonstrated for isothermal room temperature separation of highly volatile compounds and temperature programmed separation with different ramping rates. In all cases, peak capacities from forward mode separations are higher than those from other modes, indicating the ability of a positive thickness gradient to focus analyte peaks. This thickness gradient technique can therefore be broadly applied to various stationary phases and column types as a general method for improving GC separation performance.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2019.460737DOI Listing

Publication Analysis

Top Keywords

thickness gradient
20
stationary phase
12
phase thickness
12
thickness
10
column
9
peak focusing
8
positive thickness
8
uniform thickness
8
thickness column
8
forward mode
8

Similar Publications

Biotic interactions-and predation in particular-are thought to follow a latitudinal gradient, increasing towards the tropics; yet empirical evidence remains contradictory and largely based on studies from the Northern Hemisphere. Moreover, the role of environmental variables shaping latitudinal gradients of predation intensity has seldom been tested. Here, we quantify predation by shell-breaking crabs on modern shells of the marine gastropod along a latitudinal gradient (40°-54° S) on the southwestern Atlantic coast.

View Article and Find Full Text PDF

Sectionally nonlinearly functionally graded (SNFG) structures with triply periodic minimal surface (TPMS) are considered ideal for bone implants because they closely replicate the hierarchical, anisotropic, and porous architecture of natural bone. The smooth gradient in material distribution allows for optimal load transfer, reduced stress shielding, and enhanced bone ingrowth, while TPMS provides high mechanical strength-to-weight ratio and interconnected porosity for vascularization and tissue integration. Wherein, The SNFG structure contains sections with thickness that varies nonlinearly along their length in different patterns.

View Article and Find Full Text PDF

Background: Proper risk stratification tools for patients with obstructive hypertrophic cardiomyopathy (oHCM) undergoing septal myectomy are lacking. Our objective was to assess the predictive value of preoperative N-terminal pro-brain natriuretic peptide (NT-proBNP) on perioperative outcomes and late survival in patients with oHCM undergoing transaortic septal myectomy.

Methods: Between 2008 and 2021, 834 patients with preoperative NT-proBNP measurements underwent septal myectomy.

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate the inherent and after cyclic loading fracture strength of implant-supported cantilevered fixed prostheses fabricated from recently introduced additively manufactured (AM) and subtractively manufactured (SM) materials, considering variations in prosthesis height.

Materials And Methods: Three cylinder-shaped master files (20 mm long and 11 mm wide) with varying heights (7, 11, and 15 mm) and a titanium-base (Ti-base) abutment space were designed. These designs were used to fabricate a total of 144 specimens with two AM resins indicated for definitive use (Crowntec; AM-CT and Flexcera Smile Ultra+; AM-FS), one high-impact polymer composite (breCAM.

View Article and Find Full Text PDF

3D-Printed Microfiltration Membranes via Dual-Wavelength Microstereolithography.

ACS Omega

September 2025

Aerospace Structures and Materials Department, Faculty of Aerospace Engineering, Delft University of Technology, Kluyverweg 1, Delft 2629HS, The Netherlands.

A new and sustainable membrane manufacturing method is 3D printing, which reduces the number of fabrication steps, waste production, and the corresponding CO emissions. It further enables fabricating membranes with well-defined pore size, shape, and configuration. Here, we study 3D printing of microfiltration membranes using a novel dual-wavelength microstereolithography method.

View Article and Find Full Text PDF