98%
921
2 minutes
20
This work focuses on the in silico evaluation of the energy deposed by MRI switched gradient fields in bulk metallic implants and the consequent temperature increase in the surrounding tissues. An original computational strategy, based on the subdivision of the gradient coil switching sequences into sub-signals and on the time-harmonic electromagnetic field solution, allows to realistically simulate the evolution of the phenomena produced by the gradient coils fed according to any MRI sequence. Then, Pennes' bioheat equation is solved through a Douglas-Gunn time split scheme to compute the time-dependent temperature increase. The procedure is validated by comparison with laboratory results, using a component of a realistic hip implant embedded within a phantom, obtaining an agreement on the temperature increase better than 5%, lower than the overall measurement uncertainty. The heating generated inside the body of a patient with a unilateral hip implant when undergoing an Echo-Planar Imaging (EPI) MRI sequence is evaluated and the role of the parameters affecting the thermal results (body position, coil performing the frequency encoding, effects of thermoregulation) is discussed. The results show that the gradient coils can generate local increases of temperature up to some kelvin when acting without radiofrequency excitation. Hence, their contribution in general should not be disregarded when evaluating patients' safety.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1361-6560/ab5428 | DOI Listing |
Arch Orthop Trauma Surg
September 2025
Department of Orthopedic Surgery, Aybars Kıvrak Orthopedics Clinic, Adana, Turkey.
Purpose: This study aimed to compare the clinical outcomes and cost-effectiveness of two widely used intramedullary fixation systems-the Proximal Femoral Nail Antirotation (PFNA) and the Proximal Femoral Nail with Talon Locking System (PFN-TLS)-in the treatment of intertrochanteric femur fractures (ITFF).
Methods: A retrospective cohort study was conducted on 118 patients aged 65-90 years who underwent surgical treatment for ITFF using either PFNA (n = 53) or PFN-TLS (n = 65). All patients were followed for a minimum of 24 months.
Int J Surg
September 2025
Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China.
Background: Precise acetabular cup placement in total hip arthroplasty (THA) heavily relies on surgeons' visual judgment of angles. However, whether inherent visual angle misperception among surgeons affects surgical outcomes remains unclear. This study is the first to reveal that surgeons universally exhibit visual angle misperception, a key factor causing the cup implant positioning deviations in THA.
View Article and Find Full Text PDFActa Ortop Mex
September 2025
Servicio de Ortopedia y Traumatología, Hospital de San Rafael, Hospitales Pascual. Cádiz, España.
Introduction: anatomical deformities such as developmental dysplasia of the hip (DDH) and Perthes disease represent a challenge for reconstruction. The use of 3D-printed models can be helpful for assessing the deformity, bone mass, implant size, and orientation.
Objectives: to prospectively evaluate the outcomes of 3D simulation in primary total hip arthroplasty.
Arch Orthop Trauma Surg
September 2025
Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
Background: Differentiating periprosthetic joint infections (PJI) from aseptic failure is challenging in total joint arthroplasty. To date, there is no consensus about the most accurate criteria to diagnose PJI. The current study compares common diagnostic PJI criteria.
View Article and Find Full Text PDFArch Orthop Trauma Surg
September 2025
Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland.
Background: Accurate acetabular cup orientation in total hip arthroplasty (THA) is crucial for successful outcomes. Intraoperative fluoroscopy may be used to evaluate acetabular cup placement. This study aimed to evaluate the accuracy of purely visual estimation of cup inclination and anteversion using intraoperative fluoroscopy, considering different surgeon experience levels and cup designs.
View Article and Find Full Text PDF