A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Determination of aflatoxins in milk sample with ionic liquid modified magnetic zeolitic imidazolate frameworks. | LitMetric

Determination of aflatoxins in milk sample with ionic liquid modified magnetic zeolitic imidazolate frameworks.

J Chromatogr B Analyt Technol Biomed Life Sci

School of Environmental Science and Engineering, Suzhou University of Science and Technology, No. 1 Kerui Road, Suzhou 215009, PR China. Electronic address:

Published: October 2019


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The ionic liquid (IL) was introduced to the synthesis system of magnetic zeolite imidazolate framework-8 (M/ZIF-8), which was benefit to the formation of binary imidazole and the co-modification of M/ZIF-8. The morphology and textural properties of ILM/ZIF-8 were characterized by SEM, TEM, BET and BJH. The crystal structural shape and size of MZIF-8 was unvaried with the interventional of IL. The ILM/ZIF-8 was applied to the concentration and determination of aflaoxins (AFB, AFB, AFG and AFG) in milk samples based on magnetic solid phase extraction (MSPE) coupled with ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). The experimental parameters of the MSPE, including amount of ILM/ZIF-8, pH, type and amount of desorption solvent, extraction time and sample volume were investigated by a univariate method and orthogonal screening. The four AFs were concentrated from the 20 mL milk when 90 mg ILM/ZIF-8 was used as magnetic adsorbent. The extraction efficiency of AFs was higher than 80.0% within 15 min. The limits of quantitative and detection were 7.5-26.7 and 2.3-8.1 ng/L, respectively. The proposed method was applied to the determination of milk samples containing trace amounts of AFs and the recoveries ranged from 79.0% to 102.5%, with RSD below 7.7%.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2019.121778DOI Listing

Publication Analysis

Top Keywords

ionic liquid
8
milk samples
8
determination aflatoxins
4
milk
4
aflatoxins milk
4
milk sample
4
sample ionic
4
liquid modified
4
magnetic
4
modified magnetic
4

Similar Publications