A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Evaluation of Physicochemical Properties of a New Calcium Silicate-based Sealer, Bio-C Sealer. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: Calcium silicate-based materials have been proposed as root canal sealers for root canal treatment. The aim of this study was to evaluate the physicochemical properties of a new calcium silicate-based sealer (Bio-C Sealer; Angelus, PR, Brazil) compared with a calcium silicate endodontic sealer (TotalFill BC Sealer; FKG Dentaire SA, La Chaux-de-Fonds, Switzerland) and an epoxy resin sealer (AH Plus; Dentsply DeTrey, Konstanz, Germany).

Methods: The setting time and flow were evaluated based on ISO 6876 standard. The pH value was evaluated after different time intervals of storage in deionized water (1, 7, 14, and 21 days). Radiopacity was evaluated by radiographic analysis in millimeters of aluminum. Solubility and volumetric change were evaluated after 30 days of immersion in distilled water. Solubility was assessed by mass loss (%), and volumetric change was evaluated by micro-computed tomographic imaging. The data were submitted to analysis of variance and Tukey statistical tests (P < .05).

Results: TotalFill BC Sealer and Bio-C Sealer were similar regarding radiopacity, volumetric change, and pH values (P > .05). Bio-C Sealer presented the shortest setting time and the highest flow and solubility (P < .05). AH Plus showed the highest radiopacity and the lowest flow, pH, solubility, and volumetric change (P < .05).

Conclusions: Bio-C Sealer showed a short setting time, alkalinization ability, and adequate flow and radiopacity as well as low volumetric change. However, this sealer had higher solubility than the rates required by ISO 6876 standard.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.joen.2019.07.006DOI Listing

Publication Analysis

Top Keywords

bio-c sealer
20
volumetric change
20
calcium silicate-based
12
sealer
12
sealer bio-c
12
setting time
12
physicochemical properties
8
properties calcium
8
silicate-based sealer
8
root canal
8

Similar Publications