Article Abstract

Purpose: To compare image quality and radiation doses for chest DECT acquired with dual-source and rapid-kV switching techniques.

Materials And Methods: Our institutional Review Board approved retrospective study included 97 patients (54 men, 43 women; 63 ± 14 years) who underwent contrast-enhanced chest DECT with both single source, rapid kV-switching (SS-DECT) and dual source (DS-DECT) techniques per standard of care departmental protocols. Reconstructed images from both scanners had identical section thickness and section interval for virtual monoenergetic and material decomposition iodine (MDI) images. Two thoracic radiologists independently evaluated all DECT for findings, quality of images, perfusion defects (MDI), and presence of artifacts. Radiation dose descriptor, size-specific dose estimates (SSDE), was recorded. Data were analyzed with Wilcoxon Signed Rank and Cohen's Kappa tests.

Results: There were no significant differences in patient weight or SSDE for the two DECT techniques (p > 0.06). Both radiologists reported no difference in lesion and artifact evaluation on the virtual monoenergetic images from either technique (p > 0.05). However, SS-DECT (in 63-71/97 patients) had substantial artifactual heterogeneity in pulmonary perfusion on MDI images compared to none on DS-DECT (p < 0.001).

Conclusion: Despite identical patients and associated radiation doses, there were substantial differences in material decomposition iodine images generated from SS-DECT and DS-DECT techniques. Pulmonary heterogeneity on MDI images from SS-DECT leads to artifactual areas of low perfusion and can confound interpretation of true pulmonary perfusion.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2019.08.008DOI Listing

Publication Analysis

Top Keywords

image quality
8
quality radiation
8
radiation doses
8
rapid kv-switching
8
dect techniques
8
chest dect
8
virtual monoenergetic
8
mdi images
8
dect
5
images
5

Similar Publications

Clinical Role of the Noninvasive Abdominal Fetal ECG in the Detection and Monitoring of Fetal Tachycardia.

Circ Arrhythm Electrophysiol

September 2025

Department of Congenital Heart Disease, Evelina London Children's Hospital, United Kingdom (S. Chivers, T.V., V.Z., S.M., G.M., W.R., E.R., D.F.A.L., T.G.D., O.I.M., G.K.S., J.M.S.).

Background: Fetal tachycardias can cause adverse fetal outcomes including ventricular dysfunction, hydrops, and fetal demise. Postnatally, ECG is the gold standard, but, in fetal practice, echocardiography is used most frequently to diagnose and monitor fetal arrhythmias. Noninvasive extraction of the fetal ECG (fECG) may provide additional information about the electrophysiological mechanism and monitoring of intermittent arrhythmias.

View Article and Find Full Text PDF

In recent AI-driven disease diagnosis, the success of models has depended mainly on extensive data sets and advanced algorithms. However, creating traditional data sets for rare or emerging diseases presents significant challenges. To address this issue, this study introduces a direct-self-attention Wasserstein generative adversarial network (DSAWGAN) designed to improve diagnostic capabilities in infectious diseases with limited data availability.

View Article and Find Full Text PDF

Few-shot learning for highly accelerated 3D time-of-flight MRA reconstruction.

Magn Reson Med

September 2025

Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.

Purpose: To develop a deep learning-based reconstruction method for highly accelerated 3D time-of-flight MRA (TOF-MRA) that achieves high-quality reconstruction with robust generalization using extremely limited acquired raw data, addressing the challenge of time-consuming acquisition of high-resolution, whole-head angiograms.

Methods: A novel few-shot learning-based reconstruction framework is proposed, featuring a 3D variational network specifically designed for 3D TOF-MRA that is pre-trained on simulated complex-valued, multi-coil raw k-space datasets synthesized from diverse open-source magnitude images and fine-tuned using only two single-slab experimentally acquired datasets. The proposed approach was evaluated against existing methods on acquired retrospectively undersampled in vivo k-space data from five healthy volunteers and on prospectively undersampled data from two additional subjects.

View Article and Find Full Text PDF

Objective: To improve B field homogeneity in prostate MR imaging and spectroscopy using a custom-designed 16-channel external local shim coil array.

Methods: In vivo prostate imaging was performed in seven healthy volunteers (mean age: 40.7 years) without bowel preparation.

View Article and Find Full Text PDF

Purpose: Targeted therapy with lenvatinib is a preferred option for advanced hepatocellular carcinoma, however, predicting its efficacy remains challenging. This study aimed to build a nomogram integrating clinicoradiological indicators and radiomics features to predict the response to lenvatinib in patients with hepatocellular carcinoma.

Methods: This study included 211 patients with hepatocellular carcinoma from two centers, who were allocated into the training (107 patients), internal test (46 patients) and external test set(58 patients).

View Article and Find Full Text PDF