Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: In preclinical studies, the Intracerebral Microinjection Instrument (IMI) has demonstrated the ability to deliver therapeutics within the brain in 3-dimensional arrays from a single overlying penetration while incurring minimal localized trauma.
Objective: To evaluate the safety and performance of the IMI in its first use in humans to deliver stem cells in complex configurations within brain regions affected by ischemic injury.
Methods: As part of a phase 1 study, 3 chronically hemiparetic motor stroke patients received intracerebral grafts of the therapeutic stem cell line, NSI-566, using the IMI and its supporting surgical planning software. The patients were 37 to 54 yr old, had ischemic strokes more than 1 yr prior to transplantation, and received Fugl-Meyer motor scale scores of 17-48 at screening. During a single surgical procedure, patients received several neural grafts (42 ± 3) within the peri-infarct region targeted strategically to facilitate neural repair.
Results: The IMI enabled multiple cellular deposits to be safely placed peripheral to stroke lesions. The procedure was well tolerated, recovery was uneventful, and there occurred no subsequent complications. The IMI performed reliably throughout the procedures without evident targeting errors. One year after transplantation, all 3 subjects displayed significant clinical improvement, and imaging analysis demonstrated occupation of infarct cavities with new tissue without tumor formation.
Conclusion: IMI technology permits unprecedented numbers of injections to be tactically placed in 3-dimensional arrays safely and reliably in human subjects.This advanced methodology can optimize the benefits of novel therapeutics by enabling versatile 3-dimensional intracerebral targeting.