Article Abstract

Commercially, there are several plates and screws for bone fracture fixation made with PLA, however, its long degradation time and lack of integration with bone structure, provides interest in research using polymers with faster degradation, such as PLGA, and together with bioceramics, in order to improve bioactivity in bone regeneration. Based on this, in this study, bone fracture fixation plates composed of PLGA polymer matrix and combinations of 5 and 10%wt. of bioceramics were processed by microinjection. The bioceramics used comprehend nanostructured hydroxyapatite (n-HA), β-tricalcium phosphate (β-TCP) and calcium phosphate with ion substitution of magnesium (Mg-Ca/P) and strontium (Sr-Ca/P). The introduction of bioceramics modified thermal and mechanical properties of the polymer. The TGA analysis showed that there was a variation on the ceramic's mass inserted in relation to the expected values (5% and 10%wt.) in all groups of biocomposites. In general, Tg values obtained by DMA were slightly increased in almost all the biocomposites. The storage modulus (E') of biocomposites was higher for almost all groups of inserted ceramics, with exception of 5%n-HA. In the flexural tests, the biocomposites obtained a great dispersion in average values of fracture loading, presented lower values in relation to pure PLGA. There were difficulties in the processing of biocomposites with Mg-Ca/P and Sr-Ca/P, a factor that can be attributed to lack of homogeneity in the material mixing process. The results suggest modifications in thermal and mechanical properties of the PLGA plates with the bioceramics insertion and provide improvement understanding about of manufactured composites with PLGA and bioceramics.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.msec.2019.05.013DOI Listing

Publication Analysis

Top Keywords

fracture fixation
12
bone fracture
8
plga bioceramics
8
thermal mechanical
8
mechanical properties
8
bioceramics
7
biocomposites
6
plga
6
bone
5
manufacturing characterization
4

Similar Publications

Background: Pressure injuries are common, difficult to manage, and carry a high economic burden. They are challenging to physicians and a burden to society.

Case Report: An 89-year-old male, who had previously undergone internal fixation with screws and rods for a right intertrochanteric fracture, developed a deep circular open ulcer measuring 11 cm × 7.

View Article and Find Full Text PDF

We aim to describe an approach for reducing the posteriorly dislocated humeral head through the rotator interval via a deltopectoral approach that is frequently utilized for internal fixation of proximal humerus fractures and fracture dislocations. The sheath of the long head of biceps (LHB) and the rotator interval capsule are opened till the glenoid; this enables access to the glenohumeral joint via the rotator interval. A long-handle Cobb elevator is introduced through the rotator interval and, under intraoperative imaging, advanced posteromedially to the dislocated humeral head.

View Article and Find Full Text PDF

Leading through expertise: a qualitative study of clinicians' experience of a paediatric clinical trial for displaced medial epicondyle fracture.

Bone Jt Open

September 2025

Kadoorie, Oxford Trauma and Emergency Care, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Oxford University, Oxford, UK.

Aims: We sought to explore staff experience of a paediatric randomized controlled trial (RCT), comparing operative fixation and nonoperative treatment for displaced medial epicondyle fractures.

Methods: A total of 20 staff (eight surgeons and 12 research delivery staff) recruiting to the RCT in 18 NHS Trusts across the UK took part in a telephone/online qualitative interview. Interviews were informed by Heideggerian Phenomenology and thematic analysis.

View Article and Find Full Text PDF

Fibrin Sealant-Assisted Fixation of an Autologous Iliac Bone Graft in Orbital Floor Reconstruction.

J Craniofac Surg

September 2025

Division of Ophthalmic Plastic and Reconstructive Surgery, Sadik Eratik Eye Institute, Haydarpasa Numune Education and Research Hospital, University of Health Sciences.

Orbital floor fractures can lead to enophthalmos and diplopia, often requiring surgical intervention to restore orbital volume. Autologous iliac bone grafts are commonly used due to their biocompatibility and mechanical stability, but achieving adequate fixation remains a challenge. Traditional fixation methods, such as plates and screws, may introduce risks of foreign body reactions, graft displacement, and surgical morbidity.

View Article and Find Full Text PDF

Purpose: This study aimed to compare the clinical outcomes and cost-effectiveness of two widely used intramedullary fixation systems-the Proximal Femoral Nail Antirotation (PFNA) and the Proximal Femoral Nail with Talon Locking System (PFN-TLS)-in the treatment of intertrochanteric femur fractures (ITFF).

Methods: A retrospective cohort study was conducted on 118 patients aged 65-90 years who underwent surgical treatment for ITFF using either PFNA (n = 53) or PFN-TLS (n = 65). All patients were followed for a minimum of 24 months.

View Article and Find Full Text PDF