A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Portable and low-cost biosensor towards on-site detection of diclofenac in wastewater. | LitMetric

Portable and low-cost biosensor towards on-site detection of diclofenac in wastewater.

Talanta

Kurt-Schwabe-Institut Meinsberg, Kurt-Schwabe-Str. 4, 04736 Waldheim, Germany; Professur für Physikalische Chemie, Mess- und Sensortechnik, Technische Universität Dresden, 01062, Dresden, Germany.

Published: October 2019


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Wastewater treatment plants are the main release sources of pharmaceutical compounds present in surface waters. Even at low concentrations, many of these substances have long-term adverse effects on the environment. For an efficient control of pharmaceutical removal, a real-time recognition is a prerequisite. Currently, quantification of such compounds is done in special equipped laboratories and is rather time-consuming and expensive. Here, we introduce a novel biosensor for the detection of the pharmaceutical compound diclofenac, which can be produced with low costs, is easy in handling and can be applied directly on-site. Recognition of diclofenac is based on genetically engineered yeast cells which produce green fluorescent protein in a diclofenac concentration-dependent manner. Centerpiece of the sensor is a foil-based microfluidic flow cell, which allows supply with nutrient solution and analyte while preventing loss of reporter cells. Readout of data is accomplished by a newly developed spectrometric detection unit. With this device, we are able to determine diclofenac concentrations in a range from 10 to 50 μM.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2019.05.058DOI Listing

Publication Analysis

Top Keywords

diclofenac
5
portable low-cost
4
low-cost biosensor
4
biosensor on-site
4
on-site detection
4
detection diclofenac
4
diclofenac wastewater
4
wastewater wastewater
4
wastewater treatment
4
treatment plants
4

Similar Publications