A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Surgical Versus Percutaneous Closure of PDA in Preterm Infants: Procedural Charges and Outcomes. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Studies comparing percutaneous closure of patent ductus arteriosus (PDA) with surgical ligation tend to exclude premature infants and have not assessed procedural charges. We compared our contemporary outcomes and charges of device closure to surgical ligation of PDA in preterm infants.

Material And Methods: Preterm infants who underwent isolated PDA closure during their newborn hospitalization (January 2014 to September 2017) were grouped based on intention to treat (surgery versus device closure). Patient demographics, procedural details, and immediate postprocedural outcomes were compared. Procedural charges for device closure versus surgical ligation were compared.

Results: Compared with the device group (n = 33), patients undergoing surgical ligation (n = 39) were younger, smaller, and required more preoperative support (P < 0.05). The procedure time was shorter for surgical ligation (P < 0.01). Although there was no procedural mortality in either group, the complication rate was higher for device closure than for surgical ligation (15.2% versus 0%; P = 0.02). The proportion of patients returning to preprocedural respiratory support by 48 h after procedure was similar. There was a higher proportion of surgical patients who required increased inotropic support in the first 24 h after procedure (P = 0.19). The procedural charges for transcatheter device closure were twice as expensive as those for surgical ligation.

Conclusions: In our early experience with percutaneous PDA closure, we found a percutaneous approach in preterm infants feasible and well tolerated. Both surgical ligation and device closure were associated with perioperative or postoperative complications. Procedural charges were higher for percutaneous closure, driven by device charge and catheterization room utilization. Further investigation is needed to establish guidelines for first-line therapy for PDA closure in preterm infants, including cost-benefit analysis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jss.2019.04.069DOI Listing

Publication Analysis

Top Keywords

surgical ligation
16
procedural charges
12
device closure
12
percutaneous closure
8
pda preterm
8
preterm infants
8
charges device
8
closure
6
surgical
5
surgical versus
4

Similar Publications