A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Improving the nondestructive analysis accuracy of liquids in a flexible container based on the multi-pathlength spectrum method. | LitMetric

Improving the nondestructive analysis accuracy of liquids in a flexible container based on the multi-pathlength spectrum method.

Rev Sci Instrum

State Key Laboratory of Precision Measurement Technology and Instrument and School of Precision Instruments and Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China.

Published: May 2019


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In order to achieve nondestructive analysis of liquid samples, the spectral analysis of solution in a flexible container is proposed in this paper. However, the difference in the flexible containers reduces the accuracy of the spectral analysis. By analyzing the relationship between the condition number of coefficient matrix (CNCM) and the solution accuracy, a method of reducing CNCM by multi-pathlength spectrum is proposed to reduce the error caused by the differences in flexible containers. To verify the feasibility of the method, different concentrations of samples were prepared with intralipids and India-ink, and polyvinyl chloride sample tubes were used as the flexible container. The experimental results show that the proposed strategy can effectively reduce the error caused by the differences in flexible containers.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.5052909DOI Listing

Publication Analysis

Top Keywords

flexible container
12
flexible containers
12
nondestructive analysis
8
multi-pathlength spectrum
8
spectral analysis
8
reduce error
8
error caused
8
caused differences
8
differences flexible
8
flexible
6

Similar Publications