98%
921
2 minutes
20
Purpose: To determine the visual outcomes of the EyeMax Mono intraocular lens (IOL) technology (London Eye Hospital Pharma, London, UK), which is a foldable and injectable hydrophobic acrylic IOL implanted as an add-on solution in pseudophakic eyes with age-related macular degeneration, in a pilot study.
Design: A prospective, interventional case series.
Participants: A total of 22 pseudophakic eyes (11 patients) with bilateral severe or intermediate dry age-related macular degeneration (AMD) (13 eyes) or stable wet AMD or disciform scarring (9 eyes) meeting the criteria for sulcal IOL implantation.
Methods: Both eyes of participating subjects underwent small-incision ciliary sulcal implantation of a hyperaspheric, soft hydrophobic acrylic intraocular lens designed to improve the quality of the retinal image in all areas of the macula ≤10° from fixation and to generate a moderate hypermetropic correction for magnification.
Main Outcome Measures: The primary outcome was safety as determined by intra- and postoperative complications, raised intraocular pressure requiring medical or surgical intervention, postoperative diplopia, reduction in visual field, and loss of ≥2 lines of visual acuity. Secondary outcomes were improvements in subjective and objective visual acuity (logarithm of the minimum angle of resolution).
Results: No intraoperative complication occurred. Elevated intraocular pressure values were measured directly after the operative procedure in 2 eyes (25 mmHg and 27 mmHg) and at the 1-week postoperative visit in 1 eye (22 mmHg) but not later. The mean postoperative spherical equivalent of refraction changed to +2.5 diopters, and all eyes had gained ≥2 lines of visual improvement (corrected distance visual acuity) by 6 months after surgery. Corrected near visual acuity as well as corrected distance visual acuity improved over time, suggesting a neuroadaptive component to improved visual function with the device. Devices were implanted bilaterally in all patients, and there were no reported symptoms of dysphotopsia or diplopia.
Conclusions: Safety concerns were not identified in the short-term or medium term. These results indicate the potential of the EyeMax Mono IOL to improve near and distance visual acuity in pseudophakic eyes with intermediate to severe AMD.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.oret.2018.02.003 | DOI Listing |
Jpn J Ophthalmol
September 2025
Department of Ophthalmology, Osaka University Graduate School of Medicine, Room E7, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan.
Abtract: PURPOSE: To evaluate the correlation between corneal backscatter and visual function in patients with Fuchs endothelial corneal dystrophy (FECD).
Study Design: Prospective case series.
Methods: This study included 53 eyes from 38 patients with FECD.
Graefes Arch Clin Exp Ophthalmol
September 2025
Department of Physics of Condensed Matter, Optics Area. Vision Research Group (CIVIUS), University of Seville, Avenida de la Reina Mercedes s/n (41012), Seville, Spain.
Purpose: To analyze the relationship between various visual function parameters (refractive status, visual acuity and contrast sensitivity) and macular pigment optical density (MPOD) values, as well as dietary intake of lutein and zeaxanthin in a pediatric population.
Methods: Thirty-six healthy White pediatric patients participated in this cross-sectional study conducted at the Optometry Clinic (Faculty of Pharmacy, Seville, Spain). MPOD values were measured using the MPSII (Macular Pigment Screener II).
J Vis
September 2025
Vrije Universiteit Amsterdam, Amsterdam Movement Sciences and Institute Brain and Behaviour Amsterdam (iBBA), Faculty of Behavioural and Movement Sciences, Amsterdam, Netherlands.
Eye tracking has the potential to be used as a meaningful measure of the consequences of vision impairment (VI), yet a comprehensive test battery is lacking. In this study, we sought to evaluate the feasibility and validity of a test battery of eye movements as a tool to measure visual performance in individuals with VI. A test battery including fixation stability, smooth pursuit, saccades, free viewing, and visual search was administered to 46 athletes with VI and 10 control participants.
View Article and Find Full Text PDFInvest Ophthalmol Vis Sci
September 2025
Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore.
Purpose: The purpose of this study was to investigate the focal relationship between choroidal thickness and retinal sensitivity in myopic eyes.
Methods: Participants underwent swept-source optical coherence tomography (SS-OCT) imaging and microperimetry testing. Choroidal thicknesses were obtained by segmenting the SS-OCT scans using a deep-learning approach.
J Refract Surg
September 2025
Cole Eye Institute, Cleveland Clinic, Cleveland, Ohio.
Purpose: To report a case of acute and transient accommodative insufficiency after laser in situ keratomileusis (LASIK) due to coronavirus disease 2019 (COVID-19).
Methods: Case report and literature review.
Results: A 36-year-old man complained of acute blurred near vision 7 days after uneventful bilateral hyperopic LASIK, concurrent with the onset of COVID-19 infection.