98%
921
2 minutes
20
Physiological closed-loop controlled medical devices automatically adjust therapy delivered to a patient to adjust a measured physiological variable. In critical care scenarios, these types of devices could automate, for example, fluid resuscitation, drug delivery, mechanical ventilation, and/or anesthesia and sedation. Evidence from simulations using computational models of physiological systems can play a crucial role in the development of physiological closed-loop controlled devices; but the utility of this evidence will depend on the credibility of the computational model used. Computational models of physiological systems can be complex with numerous non-linearities, time-varying properties, and unknown parameters, which leads to challenges in model assessment. Given the wide range of potential uses of computational patient models in the design and evaluation of physiological closed-loop controlled systems, and the varying risks associated with the diverse uses, the specific model as well as the necessary evidence to make a model credible for a use case may vary. In this review, we examine the various uses of computational patient models in the design and evaluation of critical care physiological closed-loop controlled systems (e.g., hemodynamic stability, mechanical ventilation, anesthetic delivery) as well as the types of evidence (e.g., verification, validation, and uncertainty quantification activities) presented to support the model for that use. We then examine and discuss how a credibility assessment framework (American Society of Mechanical Engineers Verification and Validation Subcommittee, V&V 40 Verification and Validation in Computational Modeling of Medical Devices) for medical devices can be applied to computational patient models used to test physiological closed-loop controlled systems.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6445134 | PMC |
http://dx.doi.org/10.3389/fphys.2019.00220 | DOI Listing |
bioRxiv
August 2025
Department of Physiology and Pharmacology, State University of New York - Downstate Health Sciences University, Brooklyn, NY 11203, USA.
Despite recent advancements in mapping thalamic and cortical projections, the specific organization of intrathalamic and corticothalamic connectivity remains elusive. Current experimental approaches cannot definitively determine whether these connections are arranged in reciprocal (closed-) or non-reciprocal (open-loop) circuits. We developed a biophysically detailed multi-compartmental model of the mouse whisker pathway, built on anatomical and physiological data.
View Article and Find Full Text PDFMov Disord Clin Pract
August 2025
Department of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Japan.
Background: Parkinson's disease (PD) often involves motor fluctuations and dyskinesia, which are difficult to manage with medication alone. Conventional deep brain stimulation (cDBS) effectively alleviates symptoms but has limitations, including the challenge of balancing therapeutic effects against potential side effects, as well as limited battery life. To address these issues, adaptive DBS (aDBS) systems, which dynamically adjust stimulation parameters based on real-time physiological feedback, have attracted growing interest.
View Article and Find Full Text PDFJ Cardiovasc Dev Dis
August 2025
Digital Engineering & Artificial Intelligence Laboratory (DEAL), Department of Critical Care Medicine, Mayo Clinic, Jacksonville, FL 32224, USA.
Heart failure, a significant global health burden, is divided into heart failure with reduced ejection fraction (HFrEF) and preserved ejection fraction (HFpEF), characterized by systolic dysfunction and diastolic stiffness, respectively. While HFrEF benefits from pharmacological and device-based therapies, HFpEF lacks effective treatments, with both conditions leading to high rehospitalization rates and reduced quality of life, especially in older adults with comorbidities. This review explores the role of artificial intelligence (AI) in advancing autonomic neuromodulation for heart failure management.
View Article and Find Full Text PDFIEEE Trans Comput Biol Bioinform
June 2025
Circular RNAs (circRNAs), a class of non-coding RNAs characterized by their covalently closed loop structures, play active roles in diverse physiological processes through interactions with biological macromolecules. Despite the growing discovery of circRNAs enabled by high- throughput technologies, their functional annotations remain largely unexplored. This highlights the need for automated batch annotation methods to unveil the functional roles of circRNAs.
View Article and Find Full Text PDFAnesthesiology
August 2025
Department of Anesthesiology, Leiden University Medical Center, Leiden, the Netherlands.
Background: Opioids are associated with potentially severe ventilatory depression. However, in the perioperative setting, when opioids are combined with anesthetics, we remain uninformed on their "isolated" effects on ventilatory control.
Methods: In twelve healthy volunteers of either sex, we tested the effect of 5 clinical doses of fentanyl (initial dose 100 µg, followed by 75 µg at t = 30 and 60 min and 50 µg at t = 90 and 120 min).