Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Timely diagnosis of tuberculosis disease is critical for positive patient outcomes, yet potentially millions go undiagnosed or unreported each year. Sputum is widely used as the testing input, but limited by its complexity, heterogeneity, and sourcing problems. Finding methods to interrogate noninvasive, non-sputum clinical specimens is indispensable to improving access to tuberculosis diagnosis and care. In this work, economical plasmonic gratings were used to analyze tuberculosis biomarker lipoarabinomannan (LAM) from clinical urine samples by single molecule fluorescence assay (FLISA) and compared with gold standard sputum GeneXpert MTB/ RIF, culture, and reference ELISA testing results.

Methods And Findings: In this study, twenty sputum and urine sample sets were selected retrospectively from a repository of HIV-negative patient samples collected before initiation of anti-tuberculosis therapy. GeneXpert MTB/RIF and culture testing of patient sputum confirmed the presence or absence of pulmonary tuberculosis while all patient urines were reference ELISA LAM-negative. Plasmonic gratings produced by low-cost soft lithography were bound with anti-LAM capture antibody, incubated with patient urine samples, and biotinylated detection antibody. Fluorescently labeled streptavidin revealed single molecule emission by epifluorescence microscope. Using a 1 fg/mL baseline for limit of detection, single molecule FLISA demonstrated good qualitative agreement with gold standard tests on 19 of 20 patients, including accurately predicting the gold-standard-negative patients, while one gold-standard-positive patient produced no observable LAM in urine.

Conclusions: Single molecule FLISA by plasmonic grating demonstrated the ability to quantify tuberculosis LAM from complex urine samples of patients from a high endemic setting with negligible interference from the complex media itself. Moreover, agreement with patient diagnoses by gold standard testing suggests that single molecule FLISA could be used as a highly sensitive test to diagnose tuberculosis noninvasively.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6435140PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0214161PLOS

Publication Analysis

Top Keywords

single molecule
20
urine samples
12
gold standard
12
molecule flisa
12
plasmonic grating
8
plasmonic gratings
8
reference elisa
8
tuberculosis
7
patient
7
samples
5

Similar Publications

Stochastic model analysis of luminescence switching in hybrid systems of CdSe/CdS quantum dots-spiropyran molecular photoswitches.

Phys Chem Chem Phys

September 2025

Department of Chemistry, Graduate School of Science and Technology, Kwansei Gakuin University, 1 Gakuen Uegahara, Sanda, Hyogo 669-1330, Japan.

Hybrid systems (HSs) of quantum dots (QDs) and molecular photoswitches exhibit luminescence switching of QDs based on energy transfer and have garnered attention for their potential applications in sensors and optical memories. In HSs, the chemical composition, such as the number of attached ligands, is inherently distributed, posing challenges for extracting the energy transfer process from the QDs to a single acceptor molecule. The stochastic model, assuming a Poisson distribution for the number of acceptors, proves to be an effective approach for extracting the process.

View Article and Find Full Text PDF

Eplet mismatch analysis in kidney transplantation: from concept to clinical practice.

Clin Transplant Res

September 2025

Department of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.

Eplet mismatch analysis offers a refined approach to assessing donor-recipient compatibility in kidney transplantation, surpassing conventional antigen-level human leukocyte antigen (HLA) matching in predicting immunologic outcomes. By identifying polymorphic amino acid residues on HLA molecules recognized by B cell receptors, this method quantifies immunologic risk. Clinical studies demonstrate that high eplet mismatch loads, particularly at HLA-DQ, are strongly associated with donor-specific antibody development, antibody-mediated rejection, and reduced graft survival.

View Article and Find Full Text PDF

Molecules with an inverted singlet-triplet gap (Δ = - < 0) hold potential for optoelectronic applications as OLEDs and photocatalysis. Despite growing interest, no single-molecule emission from a chiral dye with an inverted gap has been reported, and only one case has shown such emission from supramolecular aggregates. Here, we present the first circularly polarized light emission (CPL) from a chiral molecule exhibiting an inverted singlet-triplet gap.

View Article and Find Full Text PDF

Glial fibrillary acidic protein (GFAP) is an astrocytic marker that can be assessed in blood using single molecule array technology. Recent studies suggest that individuals with posttraumatic stress disorder (PTSD) have suppressed circulating levels of this CNS biomarker. This study examined the hypothesis that PTSD and plasma GFAP levels share common genetic and epigenetic pathways.

View Article and Find Full Text PDF

Maintaining safe and potent drug levels in vivo is challenging. Multidomain peptides assemble into supramolecular hydrogels with a well-defined, highly porous nanostructure that makes them attractive for drug delivery. However, their ability to extend release is typically limited by rapid drug diffusion.

View Article and Find Full Text PDF