Factors Impacting False Positive Recall in Screening Mammography.

Acad Radiol

The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, 601 North Caroline Street, Suite 4120E, Baltimore, MD 21287. Electronic address:

Published: November 2019


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Rationale And Objectives: Our objective was to identify factors impacting false positive recalls in screening mammography.

Materials And Methods: We retrospectively reviewed our screening mammography database from August 31, 2015 to September 30, 2016, including full field digital mammograms (FFDM) and digital breast tomosynthesis (DBT) mammograms. False positive (FP) exams were defined as Breast Imaging-Reporting and Data System (BI-RADS) 1 or 2 assessments at diagnostic imaging with 1 year cancer-free follow-up, Breast Imaging-Reporting and Data System 3 assessment at diagnostic imaging with 2 years cancer free follow-up, or biopsy with benign pathology. True positives were defined as malignant pathology on biopsy or surgical excision. We evaluated the association of FP recalls with multiple patient-level factors and imaging features.

Results: A total of 22,055 screening mammograms were performed, and 1887 patients were recalled (recall rate 8.6%). Recall rate was lower for DBT than full field digital mammograms (8.0% vs 10.6%, p < 0.001). FP results were lower if prior mammograms were available (90.8% vs 95.8%, p = 0.02), and if there was a previous benign breast biopsy (87.6% vs 92.9%, p = 0.01). Mean age for the FP group was lower than the true positive group (56.1 vs 62.9 years, p < 0.001). There were no significant differences in FP recalls based on history of high-risk lesions, family history of breast or ovarian cancer, hormone use, breast density, race, or body mass index.

Conclusion: FP recalls were significantly less likely with DBT, in older women, in patients with prior mammograms available for comparison, and in patients with histories of benign breast biopsy. This study supports the importance of using DBT in the screening setting and obtaining prior mammograms for comparison.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.acra.2019.01.020DOI Listing

Publication Analysis

Top Keywords

false positive
12
prior mammograms
12
factors impacting
8
impacting false
8
screening mammography
8
full field
8
field digital
8
digital mammograms
8
breast imaging-reporting
8
imaging-reporting data
8

Similar Publications

It is claimed that polygenic risk scores will transform disease prevention, but a typical polygenic risk score for a common disease only detects 11% of affected individuals at a 5% false positive rate. This level of screening performance is not useful. Claims to the contrary are either due to incorrect interpretation of the data or other influences.

View Article and Find Full Text PDF

Importance: Right anomalous aortic origin of a coronary artery (R-AAOCA) is a rare congenital condition increasingly diagnosed with the growing use of cardiac imaging. Due to dynamic compression of the anomalous vessel, invasive fractional flow reserve (FFR) during a dobutamine-atropine volume challenge (FFR-dobutamine) is considered the reference standard. A reliable alternative method is needed to reduce extensive invasive testing, but it remains uncertain whether noninvasive imaging can accurately assess the hemodynamic relevance of R-AAOCA.

View Article and Find Full Text PDF

Purpose: Melbourne rapid fields (MRF) online perimetry is web-based software that allows white-on-white threshold perimetry using any computer. This study assesses the perimetric outcomes of MRF10-2 protocol via laptop computer in comparison to Humphrey field analyzer (HFA).

Methods: This prospective and cross-sectional study included 91 eyes from 91 Japanese glaucoma patients.

View Article and Find Full Text PDF

Human-associated metagenomic data often contain human nucleic acid information, which can affect the accuracy of microbial classification or raise ethical concerns. These reads are typically removed through alignment to the human genome using various metagenomic mapping tools or human reference genomes, followed by filtration before metagenomic analysis. In this study, we conducted a comprehensive analysis to identify the optimal combination of alignment software and human reference genomes using benchmarking data.

View Article and Find Full Text PDF

Aim: Hepatitis C virus (HCV) infection remains a global health concern. Although the World Health Organization (WHO) proposed a strategy to eliminate HCV by 2030, Japan faces challenges owing to limited access and insufficient support for high-risk populations. Previously, HCV diagnoses required a two-step process, delaying results and increasing costs.

View Article and Find Full Text PDF