Article Abstract

This paper proposes a microcontroller-based measurement system to detect and confirm the presence of a subject in a chair. The system relies on a single Force Sensing Resistor (FSR), which is arranged in the seat of the chair, that undergoes a sudden resistance change when a subject/object is seated/placed over the chair. In order to distinguish between a subject and an inanimate object, the system also monitors small-signal variations of the FSR resistance caused by respiration. These resistance variations are then directly measured by a low-cost general-purpose microcontroller unit (MCU) without using either an analogue processing stage or an analogue-to-digital converter. Two versions of such a MCU-based circuit are presented: one to prove the concept of the measurement, and another with a smart wake-up (generated by the sudden resistance change) intended to reduce the energy consumption. The feasibility of the proposed measurement system is experimentally demonstrated with subjects of different weight sitting at different postures, and also with objects of different weight. The MCU-based circuit with a smart wake-up shows a standby current consumption of 800 nA, and requires an energy of 125 µJ to carry out the measurement after the wake-up.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6387014PMC
http://dx.doi.org/10.3390/s19030699DOI Listing

Publication Analysis

Top Keywords

measurement system
8
sudden resistance
8
resistance change
8
mcu-based circuit
8
smart wake-up
8
seat occupancy
4
occupancy detection
4
detection based
4
based low-power
4
low-power microcontroller
4

Similar Publications

Background: Diabetic foot ulcers (DFUs) are a major clinical challenge, particularly among patients with refractory ulcers, that often lead to severe complications such as infection, amputation, and high mortality. Innovations supported by strong clinical evidence have the potential to improve healing outcomes, enhance quality of life, and reduce the economic burden on individuals and health care systems.

Objective: To describe the design of the concurrent optical and magnetic stimulation (COMS) therapy Investigational Device Exemption (IDE) study for refractory DFUs (MAVERICKS) trial.

View Article and Find Full Text PDF

Background: A clear understanding of minimal clinically important difference (MCID) and substantial clinical benefit (SCB) is essential for effectively implementing patient-reported outcome measurements (PROMs) as a performance measure for total knee arthroplasty (TKA). Since not achieving MCID and SCB may reflect suboptimal surgical benefit, the primary aim of this study was to use machine learning to predict patients who may not achieve the threshold-based outcomes (i.e.

View Article and Find Full Text PDF

Arthroplasty surgery is a common and successful end-stage intervention for advanced osteoarthritis. Yet, postoperative outcomes vary significantly among patients, leading to a plethora of measures and associated measurement approaches to monitor patient outcomes. Traditional approaches rely heavily on patient-reported outcome measures (PROMs), which are widely used, but often lack sensitivity to detect function changes (e.

View Article and Find Full Text PDF

Evidence-based practices (EBPs) are most effective when they are delivered with a high degree of fidelity, or as they are intended to be delivered. Because clinicians often deviate from fidelity, it is important to monitor EBP fidelity over time to guide corrective actions. However, little is known about current fidelity monitoring practices in community behavioral health care.

View Article and Find Full Text PDF