A modified trace metal detection test for secondary imprints on porous substrates: A preliminary study.

Forensic Sci Int

School of Forensic Science, People's Public Security University of China, No. 1 Muxidi Nanli, Xicheng District, Beijing 100038, China.

Published: March 2019


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In the investigation of criminal cases involving metallic weapons such as firearms and knives, the trace metal detection test (TMDT) and the transfer detection technique are two effective and on-the-spot methods to link a suspect and a suspected metallic weapon. In general, these tests need to be conducted on suspects' hands or done by lifting trace metals from their hands within 3 days of the crime being committed. However, if no suspects are arrested within this period, neither of these two techniques is applicable. This paper presents preliminary development of a modified TMDT to overcome the intrinsic disadvantages of conventional TMDTs. The method primarily focuses on the secondary imprints on porous substrates that are transferred unconsciously from the palms of criminals after handling galvanized weapons. The modified TMDT was established by studying the effect of various factors on secondary imprints on porous substrates. We also tested the effectiveness of the modified TMDT for common porous substrates and galvanized weapons and its relative sensitivity in a depletion series. Additionally, the storage conditions of the developed secondary imprints as physical evidence were studied under different time lapses and light conditions. Finally, we proposed an improved procedure for detecting metal traces formed in the use of metallic weapons and subsequent activities at a crime scene. The modified TMDT provides a novel method for investigators to demonstrate the relationship between a suspect and a metallic weapon, thus reducing the heavy reliance of conventional TMDTs on suspects and the time limit available to visualize or lift metal traces. For this reason, it can be used as a complementary and remedial method for conventional TMDTs, especially when suspects are not arrested within 3 days of the commission of a crime. Furthermore, the improved procedure can serve as a guide for investigators to apply the TMDT series properly to solving the cases involving metallic weapons.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.forsciint.2018.09.020DOI Listing

Publication Analysis

Top Keywords

secondary imprints
16
porous substrates
16
modified tmdt
16
imprints porous
12
metallic weapons
12
conventional tmdts
12
trace metal
8
metal detection
8
detection test
8
cases involving
8

Similar Publications

In this study, a novel As(V) ion-imprinted and 4-picolinic acid (4-PA)-grafted porous diatomite (DE)-based adsorbent (As(V)-IID) was prepared by using the surface ion imprinting technique. The results of the selective adsorption experiment show that the adsorption capacity of As(V) on As(V)-IID reaches 62.78 mg/g in a solution with an initial As(V) concentration of 25 mg/L and a pH value that is near pH 4.

View Article and Find Full Text PDF

Background: Infertility is a growing global challenge, with ARTs significantly improving birth rates for infertile couples. However, ART conceptions are associated with a higher risk of negative obstetrical and perinatal outcomes, with potential long-term effects on offspring health. Many pre-implantation embryos exhibit abnormal morphokinetics, implantation failure, or arrested development.

View Article and Find Full Text PDF

Originally defined in the context of influenza vaccines by Thomas Francis Jr. in the late 1950s, original antigenic sin (OAS) refers to the tendency of the immune system to preferentially recall B cell memory against primary antigen after secondary exposure to different but related antigen. This competes with the elicitation of antibodies by lowering the frequency of antigen reception by the naïve B cell lymphocyte pool residing within secondary lymphoid organs.

View Article and Find Full Text PDF

Electrochemical dengue sensor based on NS1 epitope-imprinted polymers.

Biosens Bioelectron

December 2025

Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Bangkok, Thailand; Flow Innovation-Research for Science and Technology Laboratories (FIRST labs), Bangkok, Thailand. Electronic address:

Dengue is a significant public health concern, particularly in tropical and subtropical regions, due to its potential severity and widespread impact. Nonstructural protein 1 (NS1) serves as a crucial biomarker for the early and rapid detection of dengue virus infection. This study introduces an electrochemical sensor utilizing an epitope imprinting approach with molecularly imprinted polymer (MIP) nanoparticles to detect dengue NS1.

View Article and Find Full Text PDF

Background/objectives: This study investigated variations in DNA methylation patterns associated with chronic pain and propensity for recurrent pressure injuries (PrI) in persons with spinal cord injury (SCI).

Methods: Whole blood was collected from 81 individuals with SCI. DNA methylation was quantified using Illumina genome-wide arrays (EPIC and EPICv2).

View Article and Find Full Text PDF