A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

An ultra-stretchable, highly sensitive and biocompatible capacitive strain sensor from an ionic nanocomposite for on-skin monitoring. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Flexible strain sensors that can be comfortably attached onto the skin for real-time and accurate detection of physiological signals are particularly important for the realization of healthcare, soft robotics and human-machine interfacing. It is still challenging to develop strain sensors that satisfy both high stretchability and high sensitivity. Here, we demonstrate an ultra-stretchable, highly sensitive and biocompatible capacitive-type strain sensor based on a nanocomposite containing ionic hydrogels and silver nanofibers (AgNFs). The sensor exhibits an ultra-high stretchability of 1000% and high sensitivity with a maximum gauge factor (GF) of up to 165. We find that the incorporation of AgNFs greatly increases the electrical-double layer (EDL) area at the hydrogel/metal interface and hence enhances by 3 orders of magnitude the strain sensitivity. With a short response time and good operation stability, the sensor and its matrix were successfully applied to monitor various physiological signals such as arm and finger motions, pulse, electrocardiographs (ECG), breath, speaking and emotion changes.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c8nr08589gDOI Listing

Publication Analysis

Top Keywords

ultra-stretchable highly
8
highly sensitive
8
sensitive biocompatible
8
strain sensor
8
strain sensors
8
physiological signals
8
high sensitivity
8
strain
5
biocompatible capacitive
4
capacitive strain
4

Similar Publications