A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Application of 640-slice CT wide-detector volume scan in low-dose CT pulmonary angiography. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Computed tomography (CT) pulmonary angiography (CTPA) examination has been frequently applied in detecting suspected pulmonary embolism (PE). How to reduce radiation dose to patients is also of concern.

Objective: To assess the value of using 640-slice CT wide-detector volume scan with adaptive statistical iterative reconstruction (ASIR) algorithm in low-dose CTPA.

Methods: Fifty-eight patients who performed with CTPA were divided into two groups randomly. In the first experimental group (n = 30), ASIR combined with volume scan were performed on the patients, while in the second conventional group (n = 28), patients received ASIR combined with conventional spiral scan. General data including age and body mass index, image quality, pulmonary arterial phase, and radiation dose were analyzed by t test in the two groups.

Results: In both groups, all images revealed the 5-order or higher pulmonary arterial branches and fully met the needs for clinical diagnosis. There was no statistical difference in general data between the two groups. In terms of pulmonary phase accuracy, compared with the conventional group, images at pulmonary arterial phase could be captured more accurately in the experimental group. CTDI in the experimental group decreased by 30% compared with that in the conventional group. The actual radiation dose in the experimental group was 1.5 mSv, which is reduced by 53% compared to that in the conventional group.

Conclusions: Compared with the conventional spiral scan, using 640-slice CT volume scan with ASIR in CTPA is more accurate in scanning phase and has lower radiation dose. There is no significant difference in image quality between the two groups.

Download full-text PDF

Source
http://dx.doi.org/10.3233/XST-180427DOI Listing

Publication Analysis

Top Keywords

volume scan
16
radiation dose
16
experimental group
16
compared conventional
16
conventional group
12
pulmonary arterial
12
640-slice wide-detector
8
wide-detector volume
8
pulmonary angiography
8
asir combined
8

Similar Publications