High-frequency oscillations (HFOs), including ripples (Rs) and fast ripples (FRs), are promising biomarkers of epileptogenesis, but their clinical utility is limited by the lack of a standardized approach to identification. We set out to determine whether electroencephalographers experienced in HFO analysis can reliably identify and quantify interictal HFOs. Two blinded raters independently reviewed 10 intraoperative electrocorticography (ECoG) samples from epilepsy surgery cases, and 10 scalp EEG samples from epilepsy monitoring unit evaluations. HFOs were visually marked using bandpass filters (R, 80-250 Hz; FR, 250-500 Hz) with a sampling frequency of 2,000 Hz. There was agreement as to the presence or absence of epileptiform discharges (EDs), Rs, and FRs, in 17, 18, and 18 cases, respectively. Interrater reliability (IRR) was favorable with κ = 0.70, 0.80, and 0.80, respectively, and similar for ECoG and scalp electroencephalography (EEG). Furthermore, interclass correlation for rates of Rs (0.99, 95% confidence interval [CI] 0.96-0.99) and FRs (0.77, 95% CI 0.41-0.91) were superior in comparison to EDs (0.37, 95% CI -0.60 to 0.75). Our data suggest that HFO identification and quantification are reliable among experienced electroencephalographers. Our findings support the reliability of utilizing HFO data in both research and clinical arenas.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6293061 | PMC |
http://dx.doi.org/10.1002/epi4.12266 | DOI Listing |
Fluids Barriers CNS
September 2025
Department of Medical Sciences, Neurology, Uppsala University, Uppsala, Sweden.
Background: Idiopathic normal pressure hydrocephalus (iNPH) predominantly manifests with gait disturbances, yet clinical assessments are vulnerable to confirmation bias, particularly post-shunt surgery. Blinded video evaluations are a method to enhance objectivity in gait assessment, but their reliability has never been systematically investigated. The aim was to evaluate the inter-rater reliability of blinded gait assessments in iNPH patients and to investigate how these assessments correlate with the Hellström iNPH scale and patient-reported health status following shunt surgery.
View Article and Find Full Text PDFEur Radiol Exp
September 2025
Center for MR-Research, University Children's Hospital Zurich, University of Zurich, Zurich, Switzerland.
Background: Fetal MRI is increasingly used to investigate fetal lung pathologies, and super-resolution (SR) algorithms could be a powerful clinical tool for this assessment. Our goal was to investigate whether SR reconstructions result in an improved agreement in lung volume measurements determined by different raters, also known as inter-rater reliability.
Materials And Methods: In this single-center retrospective study, fetal lung volumes calculated from both SR reconstructions and the original images were analyzed.
Zhonghua Jie He He Hu Xi Za Zhi
September 2025
Department of Respiratory and Critical Care Medicine, the Second Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing 210009, China.
Severe pneumonia, as a critical and prevalent condition of the respiratory system, poses a significant threat to patient survival and health outcomes. This article focuses on the similarities and differences between community-acquired pneumonia (CAP) and hospital-acquired pneumonia (HAP)/ventilator-associated pneumonia (VAP). There is significant divergence in the predominant pathogens between severe community-acquired pneumonia (SCAP) and HAP/VAP.
View Article and Find Full Text PDFSeizure
August 2025
Serviço de Neurologia, Departamento de Neurociências e Saúde Mental, Hospital Santa Maria, Unidade Local de Saúde Santa Maria, Lisboa, Portugal; Centro de Estudos Egas Moniz, Faculdade de Medicina, Universidade de Lisboa, 1649-028 Lisboa, Portugal; Laboratório de EEG/Sono, Serviço de Neurologi
Introduction: Subtle involuntary movements in patients with impaired awareness may suggest non-convulsive status epilepticus (NCSE), but their diagnostic accuracy is unclear. Since electroencephalography (EEG) is not always available, clinicians often rely on motor signs for early diagnosis. We aimed to characterize these movements and evaluate interrater agreement and diagnostic accuracy among specialists.
View Article and Find Full Text PDFJ Forensic Leg Med
August 2025
Laboratory of Criminalistics, Adam Mickiewicz University in Poznań, al. Niepodległości 53, Poznań 61-714, Poland; Center for Advanced Technologies, Adam Mickiewicz University in Poznań, ul. Uniwersytetu Poznańskiego 10, Poznań 61-614, Poland.
This study examines the reliability of fingerprint experts in assessing the individualization value of minutiae during the analysis of latent fingerprint traces. Despite the widespread use of fingerprint evidence in criminal investigations, growing concerns about examiner variability and the lack of verification protocols have prompted critical scrutiny of forensic practices. In this study, 30 Polish fingerprint experts were asked to identify and evaluate seven minutiae in two fingerprint traces of differing quality.