Transtibial amputee gait during slope walking with the unity suspension system.

Gait Posture

Ottawa Hospital Research Institute, Centre for Rehabilitation Research and Development, Ottawa, Canada; Canadian Forces Health Services, Ottawa, Canada. Electronic address:

Published: September 2018


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: People with lower limb amputation may experience walking limitations on slopes because of missing musculoskeletal and neuromuscular systems. Elevated vacuum suspension could benefit transtibial amputee gait for slope walking, but research is lacking to inform clinical practice.

Methods: Twelve people with unilateral transtibial amputation were fitted with the Unity elevated vacuum suspension system (Össur) and Pro-Flex XC foot. 3D motion analysis was performed for 7° incline, 7° decline, and level walking within a CAREN-Extended system virtual Park environment. Randomized and blinded walking trials were completed with the vacuum active or inactive.

Results: Statistically significant differences (p < 0.05) were found between vacuum conditions when walking uphill or downhill for temporal spatial, kinematic, and kinetic gait parameters; however, effect sizes were small (r≤0.35). Prosthetic step length decreased for both vacuum conditions on downhill compared to uphill walking. Symmetry index was <10% for step length, step time, and stance time for both vacuum condition during downhill walking, indicating acceptable symmetry. During incline walking, step length was only symmetrical with active vacuum. Knee range of motion was not restricted, for both conditions.

Conclusion: Active vacuum improved gait symmetry for incline walking, but the other differences between vacuum conditions were small and may not be clinically significant. Therefore, the Unity system approach for elevated vacuum suspension had a positive, but small, effect on walking and should maintain appropriate walking even with vacuum failure, until limb volume changes adversely affect socket fit (i.e., elevated vacuum helps control limb volume fluctuations over time).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.gaitpost.2018.07.059DOI Listing

Publication Analysis

Top Keywords

transtibial amputee
8
amputee gait
8
gait slope
8
slope walking
8
suspension system
8
elevated vacuum
8
vacuum suspension
8
walking
5
walking unity
4
unity suspension
4

Similar Publications

Background:  Lower limb amputation (LLA) significantly affects mobility and increases fall risk, particularly in individuals with higher-level amputations and lower functional capacity. Effective tools to assess fall risk are essential in rehabilitation.

Objective: This study was conducted at the Department of Physical Medicine and Rehabilitation, Coimbra University Hospital (HUC), Coimbra, Portugal.

View Article and Find Full Text PDF

Background: Prosthetic alignment is a critical factor in the functionality and comfort of transtibial prostheses, which are still based on amputee's feedback prosthetist experience and clinical judgment. Proper alignment involves a series of procedures, including bench, static, and dynamic alignment, each contributing to the overall success of the prosthesis.

Objective: This cross-sectional study aims to explore transtibial prosthetic alignment practices among prosthetists in Malaysia, Jordan, and Saudi Arabia, focusing on the associations of demographic data, occupational status, and knowledge on common prosthetic alignment guidelines.

View Article and Find Full Text PDF

This study investigates the structural and functional characteristics of residual muscles in transtibial amputees (TTAs) to improve electromyography (EMG)-based prosthetic control. Using ultrasonography, we measured the thickness of the Tibialis Anterior (TA), Peroneus Longus (PL), Gastrocnemius Medialis (GM), and Lateralis (GL) at rest and during contraction. Surface EMG was employed to assess muscle activation patterns, co-contraction levels, and accuracy in modulating submaximal contractions at 25%, 50%, and 75% of maximum voluntary contraction (MVC).

View Article and Find Full Text PDF

Lower limb amputation greatly affects quality of life by restricting functional mobility. Despite advancements in prosthetic design, powered transtibial prostheses still have limitations in user control and adaptability to dynamic environments. This research presents a comparative analysis between a novel electromyography (EMG)-driven variable impedance controller (VIC) and a hybrid controller (HC) that integrates a volitional EMG-driven musculoskeletal model with a finite-state machine impedance controller.

View Article and Find Full Text PDF

Navigating changes in surface height is a component of daily living, requiring different musculoskeletal demands compared with level-ground walking. Individuals with transtibial amputation commonly adopt a hip-dominant strategy to compensate for the absence of active ankle plantar flexor power. Recent tests of overground walking with a direct control myoelectric bionic prosthesis found that participants exhibited similar prosthesis torques and powers to their passive devices, likely due to persistent motor memory.

View Article and Find Full Text PDF