Implementation of a Piezo-diagnostics Approach for Damage Detection Based on PCA in a Linux-Based Embedded Platform.

Sensors (Basel)

Centro de Crecimiento Empresarial MacondoLab, Universidad Simón Bolívar (UIS), Barranquilla 080001, Colombia.

Published: November 2018


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The implementation of damage-detection methods for continuously assessing structural integrity entails systems with attractive features such as storage capabilities, memory capacity, computational complexity and time-consuming processing. In this sense, embedded hardware platforms are a promising technology for developing integrated solutions in Structural Health Monitoring. In this paper, design, test, and specifications for a standalone inspection prototype are presented, which take advantage of piezo-diagnostics principle, statistical processing via Principal Component Analysis (PCA) and embedded systems. The equipment corresponds to a piezoelectric active system with the capability to detect defects in structures, by using a PCA-based algorithm embedded in the Odroid-U3 ARM Linux platform. The operation of the equipment consists of applying, at one side of the structure, wide guided waves by means of piezoelectric devices operated in actuation mode and to record the wave response in another side of the structure by using the same kind of piezoelectric devices operated in sensor mode. Based on the nominal response of the guide wave (no damages), represented by means of a PCA statistical model, the system can detect damages between the actuated/sensed points through squared prediction error (Q-statistical index). The system performance was evaluated in a pipe test bench where two kinds of damages were studied: first, a mass is added to the pipe surface, and then leaks are provoked to the pipe structure by means of a drill tool. The experiments were conducted on two lab structures: (i) a meter carbon-steel pipe section and (ii) a pipe loop structure. The wave response was recorded between the instrumented points for two conditions: (i) The pipe in nominal conditions, where several repetitions will be applied to build the nominal statistical model and (ii) when damage is caused to the pipe (mass adding or leak). Damage conditions were graphically recognized through the Q-statistic chart. Thus, the feasibility to implement an automated real-time diagnostic system is demonstrated with minimum processing resources and hardware flexibility.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6264083PMC
http://dx.doi.org/10.3390/s18113730DOI Listing

Publication Analysis

Top Keywords

side structure
8
piezoelectric devices
8
devices operated
8
wave response
8
statistical model
8
pipe
7
implementation piezo-diagnostics
4
piezo-diagnostics approach
4
approach damage
4
damage detection
4

Similar Publications

Foramen on Frontal Process of Zygomatic Bone.

J Craniofac Surg

September 2025

Department of Anatomy, UP University of Medical Sciences, Saifai, Etawah, UP, India.

Foramina in the orbit are well described in the literature. But the author of the present study observed an unusual foramen in the frontal process of the zygomatic bone, not reported so far, as far as the author knows. This foramen was observed in 2 skulls, in one skull bilaterally and in another skull unilaterally on the left side.

View Article and Find Full Text PDF

A qualitative study to investigate pharmacovigilance systems in Dubai hospitals.

PLoS One

September 2025

Discipline of Clinical Pharmacy, School of Pharmaceutical Sciences, University Sains Malaysia, Penang, Malaysia.

Background: Ensuring the safety of medications is a significant public health priority, with developed countries implementing robust pharmacovigilance programs. Despite this, healthcare providers continue to underreport adverse drug reactions (ADRs). This study aims to explore the existing pharmacovigilance system and procedure followed for ADR reporting in selected Dubai hospitals.

View Article and Find Full Text PDF

Background: Immune checkpoint inhibitors (ICIs) are widely used in cancer therapy, yet diagnosing and managing immune-related adverse events (irAEs) remains challenging in clinical practice. Differences in healthcare structures between university hospitals (UH) and private practices (PP) influence irAE presentation and management, often excluding the latter from analyses.

Patients And Methods: This retrospective study included 604 cancer patients treated with ICIs between 2014 and 2023: 323 from UH and 281 from PP.

View Article and Find Full Text PDF

The anterior commissure (AC) has an anterior and posterior limb. Despite comprehensive information about the posterior limb, there is limited and conflicting information about the anterior limb in the literature. We aimed to show the anatomical relationships of the AC with neighboring structures by using white matter microdissection and magnetic resonance (MR) tractography, primarily on the anterior limb of the AC.

View Article and Find Full Text PDF

Liquid crystal elastomers (LCEs) are important soft actuators that show strong promise in many fields where traditional rigid actuators or robotics are impractical. However, their real-world applications are lacking primarily due to inadequate actuation performance and complicated fabrication processes. Here, a novel design is reported that significantly enhances actuation performance while simplifying the fabrication process.

View Article and Find Full Text PDF