98%
921
2 minutes
20
Image guidance improves tissue sampling during biopsy by allowing the physician to visualize the tip and trajectory of the biopsy needle relative to the target in MRI, CT, ultrasound, or other relevant imagery. This paper reports a system for fast automatic needle tip and trajectory localization and visualization in MRI that has been developed and tested in the context of an active clinical research program in prostate biopsy. To the best of our knowledge, this is the first reported system for this clinical application and also the first reported system that leverages deep neural networks for segmentation and localization of needles in MRI across biomedical applications. Needle tip and trajectory were annotated on 583 T2-weighted intra-procedural MRI scans acquired after needle insertion for 71 patients who underwent transperineal MRI-targeted biopsy procedure at our institution. The images were divided into two independent training-validation and test sets at the patient level. A deep 3-D fully convolutional neural network model was developed, trained, and deployed on these samples. The accuracy of the proposed method, as tested on previously unseen data, was 2.80-mm average in needle tip detection and 0.98° in needle trajectory angle. An observer study was designed in which independent annotations by a second observer, blinded to the original observer, were compared with the output of the proposed method. The resultant error was comparable to the measured inter-observer concordance, reinforcing the clinical acceptability of the proposed method. The proposed system has the potential for deployment in clinical routine.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6450731 | PMC |
http://dx.doi.org/10.1109/TMI.2018.2876796 | DOI Listing |
Eur Urol Oncol
September 2025
Department of Urology, New York Presbyterian Hospital, Weill Cornell Medicine, New York, NY, USA. Electronic address:
Background And Objective: The apex-to-base transperineal (TP) prostate biopsy needle trajectory may better sample the anterior prostate than the transrectal approach. There is evidence that African American men are more likely to harbor anterior tumors, suggesting that TP biopsy would result in better detection in these men. We performed a secondary retrospective analysis of prospective randomized trial data to determine whether African American race is associated with anterior tumor location and better detection with TP biopsy.
View Article and Find Full Text PDFJ Am Vet Med Assoc
August 2025
Objective: To provide a video tutorial on ultrasound-guided arthrocentesis and injection of the canine elbow and stifle joints.
Animals: Dogs undergoing arthrocentesis or IA injections for diagnostic or therapeutic purposes.
Methods: The target joint is visualized in long axis with a 70% isopropyl alcohol medium and linear array probe with a frequency range of 2 to 14 MHz and a footprint of 50 mm after clipping a window and preparing the region sterilely.
Sci Rep
August 2025
Bio-Inspired Technology (BITE) Group, Department of BioMechanical Engineering, Faculty of Mechanical Engineering, Delft University of Technology, Delft, The Netherlands.
Positioning a thin needle into a solid substrate near a target region is difficult because the needle can easily bend and buckle. Nevertheless, in nature, female parasitic wasps can do this by using buckling prevention and steering mechanisms. This study presents a self-propelled needle that incorporates wasp-inspired steering mechanisms, specifically, the use of pretension and asymmetry within the needle segments.
View Article and Find Full Text PDFFront Bioeng Biotechnol
August 2025
Shanghai Key Laboratory of Acupuncture Mechanism and Acupoint Function, College of Biomedical Engineering, Fudan University, Shanghai, China.
Objective: Traditional manual acupuncture faces challenges in quantifying stimulation parameters and preserving techniques consistency. This study presents a robot arm-assisted acupuncture system replicating manual manipulations with precise motion and force monitoring.
Methods: System validation was conducted through a Laser Vibrometer to measure multiple frequency-amplitude combinations, followed by comparative analysis between robotic and manual acupuncture manipulations using both motion and force monitoring.
J Orthop Surg Res
August 2025
Department of Orthopedics, Second Hospital of Shanxi Medical University, Taiyuan, 030001, China.
Objectives: This study aimed to evaluate the effectiveness of 3D-printed guide plate-assisted descending INFIX technology in the management of unstable pelvic ring injuries.
Methods: This retrospective study analyzed the clinical data of 51 patients who underwent INFIX surgery for pelvic ring fractures at the Second Hospital of Shanxi Medical University between January 2023 and December 2024. Based on the use of 3D-printed guide plates, the patients were divided into two groups: conventional group ( = 28) and guide plate group ( = 23).