Objective: Officially licensed hybrid closed-loop systems are not currently available worldwide; therefore, open-source systems have become increasingly popular. Our aim was to assess the safety, feasibility, and efficacy of an open-source hybrid closed-loop system (AndroidAPS) versus SmartGuard technology for day-and-night glucose control in children under extreme sports conditions.
Research Design And Methods: Twenty-two children (16 girls, 6-15 years of age, median HbA1c 56 ± 9 mmol/mol) were enrolled in this pivotal winter sports camp study. The participants were divided into two groups using either the AndroidAPS or SmartGuard technology. Physical exertion was represented by all-day alpine skiing. The primary endpoints were mean glucose level, time below the threshold of 3.9 mmol/L, and time within the target range of 3.9 to 10 mmol/L.
Results: The children using the AndroidAPS had significantly lower mean glycemia levels (7.2 ± 2.7 vs. 7.7 ± 2.8 mmol/L; 129.6 ± 49 vs. 138.6 ± 50 mg/dL, P < 0.042) than the children using the SmartGuard. The proportion of time below the target (median 5.0% ± 2.5% vs. 3.0% ± 2.3%, P = 0.6) and in the target zone (63% ± 9.5% vs. 63% ± 18%, P = 0.5) did not significantly differ. The AndroidAPS group experienced more frequent malfunctions of the cannula set (median 0.8 ± 0.4 vs. 0.2 ± 0.4, P = 0.02), which could have affected the results. No significant difference was found in the amount of carbohydrates consumed for the prevention and treatment of hypoglycemia [median 40 ± 23 vs. 25 ± 29 g/(patient ·3 days)]. No episodes of severe hypoglycemia or other serious adverse events were noted.
Conclusions: This pilot study showed that the AndroidAPS system was a safe and feasible alternative to the SmartGuard Technology.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1089/dia.2018.0214 | DOI Listing |
G Ital Nefrol
August 2025
Infermiere Professionale SSD Nefrologia e Dialisi P.O. Soverato, ASP CZ.
Management of diabetes mellitus in hemodialysis is highly complex due to increased glycemic variability and hypoglycemic risk. The use of technologies applied to diabetes has been shown to improve glycemic control, however data in dialysis patients are limited. To describe the efficacy and safety of the minimed 780G AHCL system in a stable hemodialysis patient and during hospitalization in the Intensive Care Unit (ICU).
View Article and Find Full Text PDFDiabetes Technol Ther
September 2025
Institute of Metabolic Science-Metabolic Research Laboratories, University of Cambridge, Cambridge, United Kingdom.
CamAPS FX is a customizable hybrid closed-loop app with a default target glucose of 105 mg/dL. The personal glucose target is user-adjustable in 1 mg/dL increments between 80 and 198 mg/dL in 30-min segments over 24 h. We assessed the impact of different personal glucose targets on glycemic control during real-world use of CamAPS FX in different age-groups.
View Article and Find Full Text PDFSci Adv
September 2025
Shanghai Key Laboratory of Flexible Medical Robotics, Tongren Hospital, Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai 200336, China.
Stereotactic neurointervention is a common procedure for biopsy, injection, ablation, and implantation of electrodes for deep brain stimulation. Guided by preoperative imaging, conventional approaches are mostly performed manually, lacking operation stability and interactive feedback. The intraoperative magnetic resonance imaging (MRI) guidance enables both structural and functional assessment during operation, permitting interactive adaptation to tissue deformation and avoidance of critical anatomical regions.
View Article and Find Full Text PDFCureus
September 2025
Department of Internal Medicine, Civil Hospital of Ovada, Ovada, ITA.
Continuous glucose monitoring (CGM) has transformed diabetes mellitus management, evolving from a supportive monitoring tool to a central pillar of care. For people with type 1 diabetes and many insulin-treated individuals with type 2 diabetes, CGM now directly informs treatment decisions, especially when integrated with automated insulin delivery (AID) systems. In these hybrid closed-loop systems, sensor data drives real-time insulin adjustments, meaning that accuracy is not just a matter of measurement quality; it is a matter of patient safety.
View Article and Find Full Text PDFJCEM Case Rep
October 2025
Servicio de Endocrinología y Nutrición, Hospital Universitario Clínico San Carlos, Madrid 28040, Spain.
This case report describes a 25-year-old woman with type 1 diabetes mellitus (T1DM) and autoimmune thyroid disease (AITD) who developed Addison disease (AD). The diagnosis was suspected due to a significant decrease in insulin requirement and recurrent hypoglycemia despite adjustments in insulin pump therapy. The patient exhibited typical clinical features of AD, including hyperpigmentation and electrolyte imbalances.
View Article and Find Full Text PDF