A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A full-automated magnetic particle-based chemiluminescence immunoassay for rapid detection of cortisol in milk. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A sensitive full-automated micromagnetic particles (MMPs) based competitive chemiluminescent immunoassay (CLIA) was developed to detect cortisol in milk. Polyclonal antibody (pAb) with good specificity against cortisol was produced. The antigen (cortisol-OVA) was labeled with acridinium ester (cortisol-OVA-AE) as signal tracer. During the detection, the free cortisol in sample will compete with cortisol-OVA-AE for binding to pAb. To capture pAb, MMPs conjugated with goat anti-rabbit IgG was added. The whole immunoassay process (exclude sample pretreatment) was performed by automatic chemiluminescence immunoassay instrument, which could consume less test time (within 40 min) and avoid error from manual operation. The method showed a good detection limit of 0.12 ng/mL, a broad linear range from 0.42 to 72.27 ng/mL for cortisol detection, negligible cross-reactivity with related analogues and satisfied recovery (84.3%-102.3%) for spiked milk samples test. Simultaneously, since the results of proposed method had no significant difference with those of LC-MS/MS, the proposed method was confirmed to have a potential applicability for rapidly monitoring cortisol in the food.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2018.06.015DOI Listing

Publication Analysis

Top Keywords

chemiluminescence immunoassay
8
cortisol milk
8
proposed method
8
cortisol
6
full-automated magnetic
4
magnetic particle-based
4
particle-based chemiluminescence
4
immunoassay
4
immunoassay rapid
4
detection
4

Similar Publications