Cardiac stroke volume (SV) is an essential hemodynamic indicator that can be used to assess whether the pump function of the heart is normal. Non-invasive SV measurement is currently performed using the impedance cardiography (ICG). In this technology, left ventricular ejection time (LVET) is an important parameter which can be determined from the ICG signals. However, the ICG signals are inherently susceptible to artificial noise interference, which leads to an inaccurate LVET measurement and then yields an error in the calculation of SV. Therefore, the goal of the study was to measure LVETs using both the transmission and reflection photoplethysmography (PPG), and to assess whether the measured LVET was more accurate by the PPG signal than the ICG signal. The LVET measured by the phonocardiography (PCG) was used as the standard for comparing with those by the ICG and PPG. The study recruited ten subjects whose LVETs were simultaneously measured by the ICG using four electrodes, the reflection PPG using neck sensors (PPG) and the transmission PPG using finger sensors (PPG). In each subject, ten LVETs were obtained from ten heartbeats selected properly from one-minute recording. The differences of the measured LVETs between the PCG and one of the ICG, PPG and PPG were -68.2 ± 148.6 ms, 4.8 ± 86.5 ms and -7.0 ± 107.5 ms, respectively. As compared with the PCG, both the ICG and PPG underestimated but the PPG overestimated the LVETs. Furthermore, the measured LVET by the PPG was the closest to that by the PCG. Therefore, the PPG may be employed to improve the LVET measurement in applying the ICG for continuous monitoring of SV in clinical settings.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6164077 | PMC |
http://dx.doi.org/10.3390/s18093036 | DOI Listing |
Acta Anaesthesiol Scand
October 2025
Department of Internal Medicine, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands.
Introduction: Sepsis remains a leading cause of mortality, with mortality from septic shock exceeding 40%. Standardized resuscitation (30 mL/kg) may cause adverse outcomes, including fluid overload or prolonged hypotension, emphasizing the need for individualized strategies. Sepsis-induced shock arises from varying degrees of vasodilation and hypovolemia, yet patients often present with similar clinical signs in the emergency department (ED).
View Article and Find Full Text PDFBioimpacts
August 2025
Electrical Department, Shahrood University of Technology, Shahrood, Iran.
Introduction: Accurate and non-invasive blood glucose estimation is essential for effective health monitoring. Traditional methods are invasive and inconvenient, often leading to poor patient compliance. This study introduces a novel approach that leverages systolic-diastolic framing Mel-frequency cepstral coefficients (SDFMFCC) to enhance the accuracy and reliability of blood glucose estimation using photoplethysmography (PPG) signals.
View Article and Find Full Text PDFProg Mol Biol Transl Sci
September 2025
Division of Sleep Medicine, Louis Stokes Cleveland VA Medical Center, Cleveland, OH, United States; Division of Pulmonary, Critical Care, and Sleep Medicine, University Hospitals Cleveland Medical Center, Cleveland, OH, United States; Department of Medicine, Case Western Reserve University, Clevelan
Obstructive sleep apnea (OSA) is a pervasive disorder characterized by recurrent airway obstructions during sleep. OSA carries serious health risks, such as cardiovascular and cognitive impairments, and imposes a significant economic burden. This chapter provides a comprehensive overview of various biosensors currently employed for OSA detection, including in-lab polysomnography and flow-based home sleep apnea testing.
View Article and Find Full Text PDFInt J Pharm
September 2025
Department of Veterinary Medicine, Central Animal Facility, Amrita Institute of Medical Sciences and Research Centre, AIMS Health Sciences Campus, Amrita Vishwa Vidyapeetham, Kochi, Kerala 682041, India.
The clinical use of gemcitabine (GEM), a frontline chemotherapeutic agent for pancreatic ductal adenocarcinoma (PDAC), is limited by its short half-life, rapid systemic clearance, associated dose-limiting toxicities and a faster development of resistance in pancreatic cancer. Aspirin (ASP), a repurposed NSAID, has been shown to sensitize PDAC cells to GEM through modulation of multiple oncogenic and inflammatory pathways. However, its clinical use is restricted by dose-dependent gastrointestinal toxicity.
View Article and Find Full Text PDFComput Methods Biomech Biomed Engin
September 2025
School of Medicine, Tzu Chi University, Hualien, Taiwan.
This study explores deep feature representations from photoplethysmography (PPG) signals for coronary artery disease (CAD) identification in 80 participants (40 with CAD). Finger PPG signals were processed using multilayer perceptron (MLP) and convolutional neural network (CNN) autoencoders, with performance assessed via 5-fold cross-validation. The CNN autoencoder model achieved the best results (recall 96.