Objectives: This study aimed to compare multipoint pacing (MPP) to optimal biventricular pacing with a quadripolar left ventricular (LV) lead and find factors associated with hemodynamic response to MPP.
Background: MPP with a quadripolar LV lead may increase response to cardiac resynchronization therapy.
Methods: Heart failure patients with a left bundle branch block underwent cardiac resynchronization therapy implantation. Q to LV sensing interval divided by the intrinsic QRS duration was measured. Invasive pressure-volume loops were assessed during 4 biventricular pacing settings and 3 MPP settings, using 4 atrioventricular delays. Hemodynamic response was defined as change in stroke work (Δ%SW) compared with baseline measurements during intrinsic conduction. Δ%SW of MPP was compared with conventional biventricular pacing using the distal electrode and the electrode with highest Δ%SW (BIV-OPT).
Results: Forty-three patients were analyzed (age 66 ± 10 years, 63% men, 30% ischemic cardiomyopathy, LV ejection fraction 29 ± 8%, and QRS duration 175 ± 13 ms). Q to local LV sensing interval corrected for QRS duration was 84 ± 8%, and variation between LV electrodes was 9 ± 5%. Compared with conventional biventricular pacing using the distal electrode, MPP showed a significant higher increase of SW (Δ%SW +15 ± 35%; p < 0.05) with a large interindividual variation. There was no significant difference in Δ%SW with MPP compared with BIV-OPT (-5 ± 24%; p = 0.19). Male sex and low LV ejection fraction were associated with increase in Δ%SW due to MPP versus BIV-OPT in multivariate analysis, while ischemic cardiomyopathy was only associated in univariate analysis.
Conclusions: Optimization of the pacing site of a quadripolar LV lead is more important than to program MPP. However, specific subgroups (i.e., especially men) may benefit substantially from MPP.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jacep.2018.02.005 | DOI Listing |
Turk Kardiyol Dern Ars
September 2025
Department of Cardiology, Necmettin Erbakan University, School of Medicine, Konya, Turkiye.
Cardiac resynchronization therapy (CRT) improves outcomes in heart failure, but prior interventions like percutaneous mitral annuloplasty may hinder lead placement. We present a 70-year-old male with ischemic cardiomyopathy and severe functional mitral regurgitation who previously received a Carillon device. Due to coronary sinus inaccessibility, left bundle branch area pacing optimized cardiac resynchronization therapy (LOT-CRT) was performed.
View Article and Find Full Text PDFHeart Rhythm
September 2025
Tufts Medicine CardioVascular Center, Division of Cardiology, Boston, MA.
Eur J Heart Fail
September 2025
Cardiology Department, University Medical Centre Ljubljana, Ljubljana, Slovenia.
Aims: There is a lack of data from randomized clinical trials comparing treatment outcomes between conduction system pacing (CSP) modalities and biventricular pacing (BVP) in symptomatic patients with refractory atrial fibrillation (AF) scheduled for atrioventricular node ablation (AVNA). The CONDUCT-AF investigates whether CSP is non-inferior to BVP in improving left ventricular ejection fraction (LVEF) and clinical outcomes in heart failure (HF) patients with symptomatic AF undergoing AVNA.
Methods: This study is an investigator-initiated, prospective, randomized, multicentre clinical trial conducted across 10 European centres, enrolling 82 patients with symptomatic AF, HF with reduced LVEF, and narrow QRS.
Eur Heart J Case Rep
September 2025
Duke University Medical Center, Division of Cardiology, Box 3182, Durham, NC 27710, USA.
Background: Genetic aetiologies of early-onset arrhythmias and cardiomyopathy (CM) are common, but timely diagnosis requires a high index of suspicion.
Case Summary: An asymptomatic 47-year-old man presented to cardiology clinic for smartwatch low-rate alarms. His brother had exertional syncope and died in his 20s from heart failure.
Heart Rhythm O2
August 2025
Joseph F. Novogratz Family Heart Rhythm Science Center, Minneapolis Heart Institute Foundation, Minneapolis, Minnesota.
Background: In 2021, Boston Scientific (BSC) announced that its Ingenio pacemakers (PMs) could exhibit high internal battery impedances (HIBIs) and trigger the safety mode (SM) that should preserve pacing when PM function is jeopardized. SM is VVI or biventricular pacing, 72.5 bpm, and unipolar, with a sensitivity of 0.
View Article and Find Full Text PDF