98%
921
2 minutes
20
The accuracy of dose calculation is vital to the quality of care for patients undergoing proton beam therapy (PBT). Currently, the dose calculation algorithms available in commercial treatment planning systems (TPS) in PBT are classified into two classes: pencil beam (PB) and Monte-Carlo (MC) algorithms. PB algorithms are still regarded as the standard of practice in PBT, but they are analytical approximations whereas MC algorithms use random sampling of interaction cross-sections that represent the underlying physics to simulate individual particles trajectories. This article provides a brief review of PB and MC dose calculation algorithms employed in commercial treatment planning systems and their performance comparison in phantoms through simulations and measurements. Deficiencies of PB algorithms are first highlighted by a simplified simulation demonstrating the transport of a single sub-spot of proton beam that is incident at an oblique angle in a water phantom. Next, more typical cases of clinical beams in water phantom are presented and compared to measurements. The inability of PB to correctly predict the range and subsequently distal fall-off is emphasized. Through the presented examples, it is shown how dose errors as high as 30% can result with use of a PB algorithm. These dose errors can be minimized to clinically acceptable levels of less than 5%, if MC algorithm is employed in TPS. As a final illustration, comparison between PB and MC algorithm is made for a clinical beam that is use to deliver uniform dose to a target in a lung section of an anthropomorphic phantom. It is shown that MC algorithm is able to correctly predict the dose at all depths and matched with measurements. For PB algorithm, there is an increasing mismatch with the measured doses with increasing tissue heterogeneity. The findings of this article provide a foundation for the second article of this series to compare MC PB based lung cancer treatment planning.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5960652 | PMC |
http://dx.doi.org/10.21037/tlcr.2018.04.05 | DOI Listing |
Pharmacoepidemiol Drug Saf
September 2025
Sanofi, Cambridge, Massachusetts, USA.
Purpose: Given the increased likelihood for individuals with severe asthma to experience comorbidities, disease complications, emergency room visits, and hospitalizations, the ability to stratify asthma populations on severity is often important. Although pharmacoepidemiologic studies using administrative healthcare databases sometimes categorize asthma severity, there is no consensus on an approach.
Methods: Individuals with asthma (≥ 2 ICD-10-CM diagnosis codes J45) aged ≥ 6 years were identified in Optum's de-identified Clinformatics Data Mart Database between January 2017 and November 2023.
Radiother Oncol
September 2025
Amsterdam UMC, Location University of Amsterdam, Department of Neurosurgery, Meibergdreef 9, Amsterdam, the Netherlands; Amsterdam Neuroscience, Amsterdam, the Netherlands; Cancer Center Amsterdam, Amsterdam, the Netherlands.
Background And Purpose: Staged Gamma Knife radiosurgery (SGKRS) delivers high-dose radiotherapy to large brain metastases (BM) in two or three fractions with a time interval of several weeks. Various systemic treatments have also demonstrated favorable intracranial responses. Therefore, the outcome of patients undergoing radiosurgery and systemic treatment for large BM is of high interest but unknown.
View Article and Find Full Text PDFInt Immunopharmacol
September 2025
The First Hospital of Anhui University of Science and Technology, Huainan 232000, China; Bengbu Medical University, Bengbu 233030, China. Electronic address:
Coal worker pneumoconiosis is an occupational pulmonary fibrosis (PF) caused by prolonged exposure to respirable coal dust (CD), with limited therapeutic options. Here, we explored the antifibrotic effects of metformin (Met) in CD-nanoparticle (CD-NP)-induced PF, focusing on its preventive and therapeutic potential. In vivo, Met was administered at different doses (low: 31.
View Article and Find Full Text PDFRes Vet Sci
September 2025
Department of Pharmacology, Faculty of Veterinary Medicine, Kasetsart University, Bangkok, Thailand. Electronic address:
Carprofen (CAR) is an NSAID commonly used in veterinary medicine that preferentially inhibits cyclooxygenase-2 (COX-2), thereby mitigating inflammation and pain while minimizing adverse effects linked to cyclooxygenase-1 (COX-1) inhibition. This study characterizes the pharmacokinetics of CAR in Siamese crocodiles (Crocodylus siamensis) and was conducted at an ambient temperature range of 27-30 °C following single intravenous (IV) or intramuscular (IM) administration at 2 mg/kg, and IM administration at 4 mg/kg. Plasma concentrations were determined using a validated high-performance liquid chromatography method with ultraviolet detection (HPLC-UV).
View Article and Find Full Text PDFEur Heart J Cardiovasc Pharmacother
September 2025
Department of Internal Medicine, University of Genova, Genova, Italy.
Aims: Several diuretic strategies, including furosemide iv boluses (FB) or continuous infusion (FC), are used in acute heart failure (AHF).
Methods And Results: We systematically searched phase 3 randomized clinical trials (RCTs) evaluating diuretic regimens in admitted AHF patients within 48 hours and irrespective of clinical stabilization. We calculated the odds ratio (OR) of FC or FB plus another diuretic (sequential nephron blockade, SNB) compared to FB alone on 24-hour weight loss (WL) and worsening renal function (WRF), with a random-effects model with inverse variance weighting.