Article Abstract

Objective: The phonatory process is often judged during sustained phonation by analyzing the acoustic voice signal and the vocal fold vibrations. Many formulas and parameters have been suggested for qualifying the characteristics of the acoustic signal and the vocal fold vibrations during sustained phonation. These parameters are directly computed from the acoustic signal and the endoscopic glottal area waveform (GAW). The GAW is calculated from laryngeal high-speed videoendoscopy (HSV) recordings and describes the increase and decrease of the glottal area during the phonation process, that is, the opening and closing of the two oscillating vocal folds over time. However, some of the parameters have strong mathematical dependencies with one another and some are ill-defined. The purpose of this study is to identify mathematical dependencies between parameters with the aim of reducing their numbers and suggesting which parameters may best describe the properties of the GAW and the acoustical signal.

Methods: In this preliminary investigation, 20 frequently used parameters are examined: 10 GAW only and 10 both GAW and acoustic parameters.

Results: In total 13 parameters can be neglected because of mathematical dependencies. In addition, nine of these parameters show problematic features that range from unexpected behavior to ill definition.

Conclusions: Reducing the number of parameters appears to be necessary to standardize vocal fold function analysis. This may lead to better comparability of research results from different studies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvoice.2018.04.011DOI Listing

Publication Analysis

Top Keywords

acoustic signal
12
vocal fold
12
mathematical dependencies
12
parameters
10
high-speed videoendoscopy
8
sustained phonation
8
signal vocal
8
fold vibrations
8
glottal area
8
gaw gaw
8

Similar Publications

Since its introduction more than 30 years ago, the blood oxygenation level-dependent (BOLD) contrast remains the most widely used method for functional MRI (fMRI) in humans and animal models. The BOLD contrast is typically acquired with echo planar imaging (EPI) to obtain sensitization of the signal during the echo time (TE) to dynamic changes in deoxyhemoglobin content, while achieving high spatiotemporal resolution and full brain coverage. However, EPI-based fMRI also faces multiple shortcomings, including sensitivity to body motion, susceptibility-related signal dropouts, interference with multimodal sensors, and loud acoustic noise.

View Article and Find Full Text PDF

Touch facilitates newborns' self-regulation: Systematic review of multidimensional arousal outcomes.

Neurosci Biobehav Rev

September 2025

Chair of Acoustics and Haptics, Centre for Tactile Internet with Human-in-the-Loop (CeTI), Technische Universität Dresden, Germany.

During the first month of life, exchanges between newborns and caregivers focus on helping babies regulate their physiological and behavioural states. Touch and bodily contact play a special role in facilitating arousal regulation and are often used to promote bonding, support at-risk babies, and manage pain. Here, we systematically review the extant evidence on the effects of touch interventions for newborns, specifically focusing on self-regulation and arousal as outcome measures.

View Article and Find Full Text PDF

Distortion products are tones produced through nonlinear effects of a system simultaneously detecting two or more frequencies. These combination tones are ubiquitous to vertebrate auditory systems and are generally regarded as byproducts of nonlinear signal amplification. It has previously been shown that several species of infectious-disease-carrying mosquitoes utilize these distortion products for detecting and locating potential mates.

View Article and Find Full Text PDF

[Lost in translation-an investigation of listening effort and performance in cochlear implant users in first and foreign language settings].

HNO

September 2025

Hörzentrum Düsseldorf, Klinik für Hals-Nasen-Ohrenheilkunde, Medizinische Fakultät und Universitätsklinikum Düsseldorf, Heinrich-Heine-Universität Düsseldorf, Moorenstr. 5, 40225, Düsseldorf, Deutschland.

Background And Objective: Speech comprehension in a foreign language under noise conditions presents an increased cognitive demand. For multilingual patients with cochlear implants (PwCI), this poses a particular challenge, as audiological routine diagnostics are typically conducted in the language of the clinical environment. This study investigates speech understanding in noise as well as the subjectively perceived listening effort in PwCI compared to normal-hearing (NH) individuals under both native and nonnative language conditions.

View Article and Find Full Text PDF

This study presents a non-destructive method for estimating surface acoustic wave attenuation, which is highly sensitive to microstructural features, especially at high frequencies. The method uses a single wideband dispersive interdigital transducer (IDT) that remotely emits acoustic waves at the sample's edge. Chirp compression of the temporal displacement response is achieved by correlating the excitation signal with the spatial configuration of the IDT's electrodes.

View Article and Find Full Text PDF