98%
921
2 minutes
20
Purpose: Transcatheter aortic valve replacement (TAVR) is a minimally invasive procedure in which a prosthetic heart valve is placed and expanded within a defective aortic valve. The device placement is commonly performed using two-dimensional (2D) fluoroscopic imaging. Within this work, we propose a novel technique to track the motion and deformation of the prosthetic valve in three dimensions based on biplane fluoroscopic image sequences.
Methods: The tracking approach uses a parameterized point cloud model of the valve stent which can undergo rigid three-dimensional (3D) transformation and different modes of expansion. Rigid elements of the model are individually rotated and translated in three dimensions to approximate the motions of the stent. Tracking is performed using an iterative 2D-3D registration procedure which estimates the model parameters by minimizing the mean-squared image values at the positions of the forward-projected model points. Additionally, an initialization technique is proposed, which locates clusters of salient features to determine the initial position and orientation of the model.
Results: The proposed algorithms were evaluated based on simulations using a digital 4D CT phantom as well as experimentally acquired images of a prosthetic valve inside a chest phantom with anatomical background features. The target registration error was 0.12 ± 0.04 mm in the simulations and 0.64 ± 0.09 mm in the experimental data.
Conclusions: The proposed algorithm could be used to generate 3D visualization of the prosthetic valve from two projections. In combination with soft-tissue sensitive-imaging techniques like transesophageal echocardiography, this technique could enable 3D image guidance during TAVR procedures.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6205814 | PMC |
http://dx.doi.org/10.1002/mp.12913 | DOI Listing |
JTCVS Open
August 2025
Department of Cardiovascular Surgery, Mayo Clinic, Rochester, Minn.
Objective: To evaluate the early postoperative morbidity, mortality, and prosthetic conduit function of patients who underwent aortic root replacement using a prefabricated bioprosthetic aortic valved conduit.
Methods: Single-center retrospective review of 124 consecutive adult patients who underwent aortic root replacement with a certified prefabricated bioprosthetic aortic valved conduit from 2021 to December 2023.
Results: Indications for operation were aortic aneurysms (n = 92), endocarditis (n = 12), deterioration of prior valve prosthesis (n = 13), and aortic dissection (n = 6).
Cureus
August 2025
Internal Medicine, Ronald Reagan University of California Los Angeles Medical Center, Los Angeles, USA.
Although generally considered harmless commensals or beneficial probiotics, species can act as opportunistic pathogens under certain clinical conditions. We describe a case of high-grade bacteremia in a 59-year-old man with a history of aortic root dilation status post Bentall procedure and bioprosthetic aortic valve replacement. The suspected source was recent dental instrumentation.
View Article and Find Full Text PDFSurg Case Rep
August 2025
Department of Cardiac and Vascular Surgery, Dokkyo Medical University School of Medicine, Shimotsugagun, Tochigi, Japan.
Introduction: Prosthetic valve endocarditis following aortic root replacement (ARR) typically necessitates redo-ARR, which involves complete graft removal, extensive aortic root dissection, and coronary reimplantation. This highly invasive procedure carries substantial surgical risk, including high operative mortality. In select high-risk patients without evidence of prosthetic graft infection, alternative surgical strategies may reduce procedural complexity and improve outcomes.
View Article and Find Full Text PDFMultimed Man Cardiothorac Surg
September 2025
Department of Cardiovascular Surgery, Marmara University Pendik Research and Training Hospital, Istanbul, Turkey.
Complete detachment of the aortic root following a Bentall procedure is an exceptionally rare complication. The vast majority of reported cases are secondary to prosthetic valve endocarditis or underlying vasculitis. Currently, the most reliable treatment for aortic root dehiscence-particularly in the context of prosthetic valve endocarditis-is repeat root replacement, typically via a second Bentall procedure or with the use of a homograft or allograft.
View Article and Find Full Text PDFJ Infect Public Health
September 2025
Department of Infectious Disease, Dijon Bourgogne University hospital, Dijon Cedex, France. Electronic address:
We report two cases of Elizabethkingia-related infective endocarditis, highlighting key risk factors such as prosthetic valve replacement. These cases underscore the need to consider endocarditis in the setting of persistent or recurrent bacteremia. Diagnosis proved challenging and required multiple imaging modalities, with positron emission tomography (PET) scan providing critical value when echocardiography was non-contributory.