98%
921
2 minutes
20
The design of medical devices is a complex and crucial process to ensure patient safety. It has been shown that improperly designed devices lead to errors and associated accidents and costs. A key element for a successful design is incorporating the views of the primary and secondary stakeholders early in the development process. They provide insights into current practice and point out specific issues with the current processes and equipment in use. This work presents how information from a user-study conducted in the early stages of the RAFS (Robot Assisted Fracture Surgery) project informed the subsequent development and testing of the system. The user needs were captured using qualitative methods and converted to operational, functional, and non-functional requirements based on the methods derived from product design and development. This work presents how the requirements inform a new workflow for intra-articular joint fracture reduction using a robotic system. It is also shown how the various elements of the system are developed to explicitly address one or more of the requirements identified, and how intermediate verification tests are conducted to ensure conformity. Finally, a validation test in the form of a cadaveric trial confirms the ability of the designed system to satisfy the aims set by the original research question and the needs of the users.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6153987 | PMC |
http://dx.doi.org/10.1007/s10439-018-2005-y | DOI Listing |
JBMR Plus
October 2025
Department of Endocrinology, Austin Health, Melbourne, 3084, Australia.
Medication-related osteonecrosis of the jaw (MRONJ) is a rare but well-recognized complication of treatment with antiresorptive agents. Medication-related osteonecrosis of the external auditory canal (MROEAC), on the other hand, is even rarer and mostly reported during bisphosphonate exposure. Its pathophysiology is thought to involve complex multifactorial processes, including inhibition of bone remodeling, altered angiogenesis, infection, and inflammation.
View Article and Find Full Text PDFJ Rehabil Med Clin Commun
September 2025
Department of Trauma and Reconstructive Surgery, Eberhard Karls University Tuebingen, BG Trauma Center Tuebingen, Tuebingen, Germany.
Objective: Acetabular fractures are among the most severe injuries in trauma surgery. In younger patients, they typically result from high-energy trauma and are often associated with polytrauma. Treatment complexity and rehabilitation outcomes are influenced by overall injury severity.
View Article and Find Full Text PDFClin Interv Aging
September 2025
Department for Orthopedics, Traumatology and Plastic Surgery, University Hospital, Leipzig, Germany.
Study Design: Systematic review.
Purpose: As the number of elderly increases, age-related changes of body composition like osteoporosis and sarcopenic muscle changes contribute to higher morbidity, less quality of life and higher health care costs. Data on the effect of muscle atrophy on osteoporotic vertebral fractures is limited.
J Ophthalmic Vis Res
September 2025
Department of Ophthalmology, Northwell Health Eye Institute, Great Neck, NY, USA.
Purpose: To report five cases of structural weakness at the haptic-optic junction of the CT Lucia 602 intraocular lens (IOL) (Carl Zeiss Meditec Inc., Dublin, CA), including two optic breakages and three optic microfractures, while using the Yamane flanged intrascleral haptic fixation surgery (FIHFS).
Methods: A retrospective chart review of five cases that underwent Yamane FIHFS by the same surgeon between 2020 and 2022 was performed.
Front Vet Sci
August 2025
Department of Veterinary Surgery, Graduate School of Veterinary Medicine, Konkuk University, Seoul, Republic of Korea.
Introduction: The conventional pin and tension band wiring (TBW) technique remains the standard for fixation, but is frequently associated with complications such as wire breakage, loosening, and delayed healing in patellar fracture. Locking plate fixation has demonstrated superior biomechanical stability in human studies. This study aimed to compare the biomechanical performance of locking plate fixation versus TBW in canine transverse patellar fractures and to evaluate the influence of plate design on fixation strength.
View Article and Find Full Text PDF