98%
921
2 minutes
20
Background: Endovascular procedures come with a potential risk of radiation hazards both to patients and to the vascular staff. Classically, most endovascular interventions took place in regular operating rooms (ORs) using a fluoroscopy C-arm unit controlled by a third party. Hybrid operating rooms (HORs) provide an optimal surgical suit with all the qualities of a fixed C-arm device, while allowing the device to be controlled by the surgical team. The latest studies suggest that an operator-controlled system may reduce the radiation dose. The purpose of the present study is to determine the amount of absorbed radiation using an HOR in comparison with a portable C-arm unit and to assess whether the radioprotection awareness of the surgical team influences the radiation exposure. The primary end point was the effective dose in milliSievert (mSv) for the surgical team and the average dose-area product (ADAP) in Gray-meters squared (Gym) for patients.
Methods: The values of absorbed radiation of the surgical team's dosimeters were collected from January 2015 to May 2016. The HOR was installed in June 2015, and a radioprotection seminar was given in October 2015. The HOR-issued radiation, measured by the maximum dose-area product, ADAP, average dose (AD) per procedure, maximum dose per procedure per month, maximum fluoroscopy time, average fluoroscopic time, peak skin dose, and average skin dose (ASD), was collected monthly from September 2015 to July 2016. The timeline was divided into 3 periods: 5 months pre-HOR (Pre-HOR), 5 months after the HOR installation (PreS-HOR), and 5 months after a radioprotection seminar (PostS-HOR).
Results: The average number of procedures per month was 22.55 (±4.9), including endovascular aneurysm repair/thoracic endovascular aneurysm repair, carotid, visceral, and upper and lower limb endovascular revascularization. The average amount of absorbed radiation by the surgeons during PreS-HOR was 1.07 ± 0.4 mSv, which was higher than the other periods (Pre-HOR 0.06 ± 0.03 mSv, P = 0.002; PostS-HOR 0.14 ± 0.09 mSv, P = 0.000, respectively). The ADAP during PreS-HOR was 0.016 ± 0.01 Gym, which was lower than the PostS-HOR (0.001 ± 0.002 Gym) (P = 0.034). The AD during PreS-HOR was 0.78 ± 0.3 Gy and 0.39 ± 0.3 Gy during PostS-HOR (P = 0.098). The ASD during PreS-HOR was 0.40 ± 0.2 Gy and 0.20 ± 0.1 Gy during PostS-HOR (P = 0.099).
Conclusions: In our experience, the HOR increases the amount of absorbed radiation for both patients and surgeons. The radioprotection seminars are of utmost importance to provide a continued training and optimize the use of ionizing radiation while using an HOR. Despite the awareness of the surgical team in the radioprotection field, the amount of absorbed radiation using an HOR is higher than the one using a C-Arm unit.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.avsg.2017.12.010 | DOI Listing |
ACS Appl Mater Interfaces
September 2025
L. V. Pisarzhevsky Institute of Physical Chemistry of NASU SE "RADMA", 31, pr. Nauky ave, Kyiv 03680, Ukraine.
The effect of electron irradiation ( = 1.8 MeV) on the optical properties of polyethylene glycol 400-multiwalled carbon nanotube (PEG-400/MWCNT) nanocomposite films was studied within an absorbed dose range of 0 to 0.4 MGy.
View Article and Find Full Text PDFObjective: To quantify C-arm-registered radiation exposure during ultrasound- and fluoroscopy-guided spinal interventional pain management in dogs, and to measure operator-based radiation levels to identify discrepancies between delivered and received dose.
Study Design: A retrospective observational study.
Animals: A total of 82 canine spinal interventional pain management procedures performed at a single referral institution.
Nuklearmedizin
September 2025
Nuclear Medicine, Ulm University Hospital, Ulm, Germany.
Silicon-based ligands are of interest in increasingly used Prostate-specific membrane antigen (PSMA) tracers for prostate cancer (PCa) staging due to their simple and scalable production. Here, we present first data on dosimetry and biodistribution of the novel PSMA-specific tracer [¹⁸F]siPSMA-14.Seven PCa patients referred for PSMA-PET/CT imaging were imaged at 60 and 120 min p.
View Article and Find Full Text PDFJ Shoulder Elbow Surg
September 2025
Department of Orthopaedic Surgery, University of California Davis, Sacramento, CA, USA. Electronic address:
Background: Computed tomography (CT) is routinely used for preoperative planning in shoulder arthroplasty. However, this practice exposes patients to ionizing radiation. This study evaluates the potential lifetime cancer risks of conventional and low-dose shoulder CT protocols.
View Article and Find Full Text PDFJ Radiat Res
September 2025
Centre for Applied Radiation Science and Technology (CARST), North-West University (Mafikeng Campus), Corner Albert Luthuli and University Drive, Private Bag X2046, Mmabatho 2735, South Africa.
Despite the environmental significance of airborne particulates generated from mine tailings, there is limited information on exposure of people living in the neighbourhoods adjacent to such sites. The main objective of the study was to assess cancer risk due to enhanced radionuclides present in dust samples and to evaluate the exposure risk of populations living in three mining areas in the Free State and West Rand in South Africa. Soil and dust samples were collected between January 2016 and March 2018 in different seasons for determination of the level of naturally occurring radioactive materials in the samples.
View Article and Find Full Text PDF