Endocr Pract
January 2025
Division of Endocrinology, Metabolism and Lipid Research, Washington University in St. Louis, School of Medicine, St. Louis, Missouri. Electronic address:
Objective: Thyroid disorders are common. Serum thyroid stimulating hormone is frequently measured and is the single best initial biomarker to diagnose thyroid disease. Automated immunoassays used to evaluate thyroid function are susceptible to interferences that can affect test results and therefore clinical decisions.
View Article and Find Full Text PDFLangmuir
June 2023
Department of Chemical and Biomolecular Engineering, University of Delaware, Allan P. Colburn Laboratory, 150 Academy Street, Newark, Delaware 19716, United States.
When monoclonal antibodies are exposed to an air-water interface, they form aggregates, which negatively impacts their performance. Until now, the detection and characterization of interfacial aggregation have been difficult. Here, we exploit the mechanical response imparted by interfacial adsorption by measuring the interfacial shear rheology of a model antibody, anti-streptavidin immunoglobulin-1 (AS-IgG1), at the air-water interface.
View Article and Find Full Text PDFtouchREV Endocrinol
November 2022
Department of Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA.
For over 50 years, immunoassays have been extensively used to quantitate hormones in blood, other fluids and tissues. Each assay has its own sensitivity, specificity and other analytical components. Despite the differences between commercial products, these assays provide important clinical information about hormone levels in patients.
View Article and Find Full Text PDFAntibodies (Basel)
March 2022
NIST Center for Neutron Research, National Institute of Standards and Technology, 100 Bureau Drive, Mail Stop 6102, Gaithersburg, MD 20899, USA.
In this study, we used sodium chloride (NaCl) to extensively modulate non-specific protein-protein interactions (PPI) of a humanized anti-streptavidin monoclonal antibody class 2 molecule (ASA-IgG2). The changes in PPI with varying NaCl () and monoclonal antibody (mAb) concentration () were assessed using the diffusion interaction parameter and second virial coefficient measured from solutions with low to moderate . The effective structure factor measured from concentrated mAb solutions using small-angle X-ray and neutron scattering (SAXS/SANS) was also used to characterize the PPI.
View Article and Find Full Text PDFClin Biochem
January 2022
Department of Pediatric Endocrinology, Ankara University Faculty of Medicine, Ankara, Turkey.
Objectives: Biotin therapy can affect the results of many immunoassay procedures. The present study investigates biotin's interference on 25-hydroxy vitamin D (25-OHD), parathyroidhormone (PTH) and thyroid-stimulating hormone (TSH) tests using four different assay systems and biotin neutralization.
Design And Methods: Enrolled in the study were 50 children diagnosed with biotinidase deficiency (BTD) undergoing treatment with biotin (5-20 mg/day) who were subjected to a series of analyses involving 25-OHD (Roche Diagnostics assays, Beckman Coulter assays, HPLC, LC/MS-MS), TSH, PTH (Roche Diagnostics assays, Beckman Coulter assays) and biotin (LC/MS-MS), before and after biotin neutralization with Streptavidin-coated magnetic particles (SMP).