Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Photooxidation and hydrolysis are the two primary aging factors of intraocular lenses. Opacifications, dislocations, glistening and yellowing of the implanted acrylic lenses, which are due to chain scissions and depolymerization, are the consequences of aging from the clinical perspective. The purpose of this study was to examine the consequence of the aging of intraocular lenses on chemical and surface properties. Acrylic lenses made of poly acrylic-co-polystyrene polymer were artificially aged by photooxidation and hydrolysis from 2 to 20 years. Degradation products were observed by Reverse-phase High-Performance Liquid Chromatography RP-HPLC and thermogravimetric analysis (TGA). The surface, which was analyzed by atomic force microscopy (AFM) and fibronectin adhesion kinetics, was chosen as an indicator of intraocular biocompatibility. Low-molecular-weight degradation products (LMWP) result from chain scission under both hydrolysis and photooxidation. The osmotic effects of water enable degradation products to migrate through the polymer. A portion of the degradation products exudate in the surrounding center, whereas a portion link with lateral chains of the polymer. At the same time, the surface roughness evolves to externalize the most hydrophilic chains. As a result, the fibronectin adhesion level decrease with time, which indicates the existence of a biocompatible kinetic for implanted intraocular lenses.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.colsurfb.2017.11.007DOI Listing

Publication Analysis

Top Keywords

intraocular lenses
16
degradation products
16
photooxidation hydrolysis
8
acrylic lenses
8
fibronectin adhesion
8
lenses
6
intraocular
5
restructuration kinetics
4
kinetics amphiphilic
4
amphiphilic intraocular
4

Similar Publications

Topic: To compare the outcomes of surgical approaches to correct ametropia following cataract and lens surgery.

Clinical Relevance: Despite advancements in the field of biometry and intraocular lens (IOL) power calculation formulas, complete elimination of refractive surprises following cataract and lens surgery is impossible. Preferred Practice Patterns acknowledges the possibility of refractive surprise following cataract surgery; however, no recommendations regarding the preferred treatment have been given.

View Article and Find Full Text PDF

Objective: Aim: To evaluate the possibility of using cataract phacoemulsification with simultaneous intraocular lens (IOL) implantation in patients with age-related cataract (ARC) combined with pseudoexfoliation syndrome (PES) as an algorithm for the pseudoexfoliation glaucoma (PEG) prevention..

Patients And Methods: Materials and Methods: A retrospective case-control study was conducted using data from medical records of 610 outpatients (813 eyes) with ARC aged from 49 to 79 years (average age 69 ± 3 years).

View Article and Find Full Text PDF

The predictive value of the orientation and offset of angle α and angle κ for visual outcomes after trifocal intraocular lens implantation in an Asian cohort.

Graefes Arch Clin Exp Ophthalmol

September 2025

Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College Hospital, No. 1 Shuaifuyuan Wangfujing Dongcheng District, China, 100730, Beijing.

Purpose: To evaluate the predictive value of the preoperative orientation and offset of angle alpha(chord alpha) and angle kappa(chord mu) for visual outcomes in patients who underwent trifocal intraocular lens (IOL) implantation.

Methods: Patient records of eyes that underwent AT LISA tri 839MP implantation were retrospectively collected and grouped according to the preoperative offset and orientations of chord alpha and chord mu. The two-dimensional location of each angle was described by the interaction of the orientation and offset.

View Article and Find Full Text PDF

Purpose: To report five cases of structural weakness at the haptic-optic junction of the CT Lucia 602 intraocular lens (IOL) (Carl Zeiss Meditec Inc., Dublin, CA), including two optic breakages and three optic microfractures, while using the Yamane flanged intrascleral haptic fixation surgery (FIHFS).

Methods: A retrospective chart review of five cases that underwent Yamane FIHFS by the same surgeon between 2020 and 2022 was performed.

View Article and Find Full Text PDF

Incision capsular bag herniation during subluxated lens surgery: mechanisms, management, and prevention.

Front Med (Lausanne)

August 2025

Eye Center, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, China.

Purpose: To investigate the mechanism, intraoperative characteristics, management, and prevention of incision capsular bag herniation (ICBH), a previously unreported complication during cataract surgery in eyes with lens subluxation.

Methods: A retrospective observational case series was conducted on five male patients who developed ICBH during phacoemulsification with intraocular lens (IOL) implantation between January 2019 and December 2024. Among 867 subluxated-lens surgeries performed during this period, the estimated incidence of ICBH was 0.

View Article and Find Full Text PDF