A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Comparison of Intraoperative Soft Tissue Balance Between Cruciate-Retaining and Posterior-Stabilized Total Knee Arthroplasty Performed by a Newly Developed Medial Preserving Gap Technique. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Medial stability of the knee is considered to be associated with good clinical results after total knee arthroplasty (TKA). This study aimed to compare intraoperative soft tissue balance between cruciate-retaining (CR) and posterior-stabilized (PS) TKA performed by a newly developed medial preserving gap technique, which aimed at preserving medial stability throughout the range of motion.

Methods: Seventy CR-TKAs and 70 PS-TKAs were performed in patients with varus type osteoarthritis with the novel technique guided by tensor measurements. Final intraoperative soft tissue balance with femoral trial component in place and patellofemoral joint reduced, including the joint component gap and varus/valgus ligament balance (varus angle), with the knee at 0° (full extension), 10° (extension), 30°, 45°, 60°, 90° (flexion), 120°, and 135° (deep flexion), was measured with Offset Repo-Tensor under 40 lbs of joint distraction force. The medial compartment gap (MCG), lateral compartment gap, and medial joint looseness (MCG-polyethylene insert thickness) at each flexion angle were calculated from the measured joint component gap and varus ligament balance, and compared between CR-TKA and PS-TKA.

Results: The MCGs from extension to deep flexion of the knee showed no significant differences between CR-TKA and PS-TKA. The lateral compartment gaps in PS-TKA from 30° to 60° of knee flexion was significantly larger than those in CR-TKA (P < .05). Medial joint looseness showed no significant differences between CR-TKA and PS-TKA which is consistent within 1 mm from extension to flexion of the knee.

Conclusion: PS-TKA similarly achieved medial stability comparable to CR-TKA using the medial preserving gap technique.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2017.09.070DOI Listing

Publication Analysis

Top Keywords

intraoperative soft
12
soft tissue
12
tissue balance
12
medial preserving
12
preserving gap
12
gap technique
12
medial stability
12
medial
9
balance cruciate-retaining
8
cruciate-retaining posterior-stabilized
8

Similar Publications