Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

We have studied the binding of busulfan (BN) to human serum albumin (HSA) at physiological pH 7.4 by using fluorescence, UV-vis and circular dichroism (CD) spectroscopic tools, as well as dynamic light scattering (DLS) measurements and molecular simulation approaches. HSA fluorescence quenching experiments showed that BN reduces the HSA native fluorescence intensity through the static mechanism. In addition, a single binding site on the HSA is occupied by BN with a binding constant at 298K of 1.84×10M. The enthalpy change (ΔH) and entropy change (ΔS) of BN-HSA interaction were calculated as -1.40kcalmol and +10.14calmolK respectively, which suggest the possible interaction mode as hydrophobic and hydrogen bonding. Moreover, the secondary structure alteration of HSA following its complexation with BN was studied and showed that α-helical content of HSA gets increased on interacting with BN. Ligand binding site to HSA was further investigated by site-specific markers in fluorescence measurements as well molecular modeling approach which indicated that BN bind to the nearby sudlow site II of HSA through hydrophobic as well as hydrogen bonding interaction. The present study will be helpful for understanding the binding mechanism of BN to human serum albumin.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijbiomac.2017.10.006DOI Listing

Publication Analysis

Top Keywords

human serum
12
serum albumin
12
site hsa
12
binding busulfan
8
busulfan human
8
hsa
8
binding site
8
hydrogen bonding
8
binding
6
investigating site
4

Similar Publications

A rapid and specific liquid chromatography-tandem mass spectrometry method with a wide linear range was developed and validated for the simultaneous quantification of Vitamin K1 (VK1) trans- and cis- isomers in human plasma. Bovine serum albumin solution (15%) served as a surrogate matrix for preparing the calibrators to establish the quantitative curves. After liquid-liquid extraction, VK1 trans- and cis- isomers in plasma samples were separated on a ChromCore C30 column (15 cm × 4.

View Article and Find Full Text PDF

Therapeutic drug monitoring (TDM) is vital for effective optimization of pharmacological treatments. In this study, we engineered a chromatography column that is sensitive to temperature fluctuations, thereby enabling safe and straightforward TDM without relying on organic solvents. Silica beads were modified by applying poly(N-isopropylacrylamide) (PNIPAAm) hydrogels, using a condensation reaction to modify the initiator, followed by radical polymerization to integrate the PNIPAAm hydrogel.

View Article and Find Full Text PDF

Background: Improving the efficacy of anti-programmed death 1 (PD-1) monoclonal antibody (mAb) therapy remains a major challenge for cancer immunotherapy in non-small cell lung cancer (NSCLC). Gut microbial metabolites can influence immunotherapy efficacy.

Methods: ELISA was used to compare the serum 5-hydroxyindoleacetic acid (5-HIAA) level in patients with NSCLC.

View Article and Find Full Text PDF

Familial hypocalciuric hypercalcaemia type 1 due to a rare missense mutation: a delayed diagnosis in a man with chronic hypercalcaemia.

BMJ Case Rep

September 2025

Diabetes and Endocrinology, North West Anglia NHS Foundation Trust, Peterborough, Cambridgeshire, UK

Familial hypocalciuric hypercalcaemia (FHH) is a rare disorder that represents a minute but important part of the differential diagnosis of hypercalcaemia. We describe a man in his 60s who was re-referred to endocrinology because of hypercalcaemia thought to be due to primary hyperparathyroidism (PHPT) that had not been followed up for 13 years. In his early 50s, the hypercalcaemia was accompanied by normal serum parathyroid hormone (PTH) levels, normal 24-hour urinary calcium excretion and normal bone density and kidney imaging, and no parathyroid adenoma was demonstrated on neck imaging.

View Article and Find Full Text PDF

Unifying serological testing for cold agglutinins.

Vox Sang

September 2025

Department of Immunohematology Diagnostics, Sanquin Diagnostic Services, Amsterdam, The Netherlands.

Background And Objectives: Cold agglutinins (CAs) are immunoglobulin M autoantibodies that optimally bind to red blood cells at low temperatures. The clinical significance of CAs is usually characterized by the CA titre and thermal amplitude. However, there is no consensus on the optimal testing strategy.

View Article and Find Full Text PDF