A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Reliability and validity of a dual-probe personal computer-based muscle viewer for measuring the pennation angle of the medial gastrocnemius muscle in patients who have had a stroke. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background A dual-probe personal computer-based muscle viewer (DPC-BMW) is advantageous in that it is relatively lightweight and easy to apply. Objective To investigate the reliability and validity of the DPC-BMW in comparison with those of a portable ultrasonography (P-US) device for measuring the pennation angle of the medial gastrocnemius (MG) muscle at rest and during contraction. Methods Twenty-four patients who had a stroke (18 men and 6 women) participated in this study. Using the DPC-BMW and P-US device, the pennation angle of the MG muscle on the affected side was randomly measured. Two examiners randomly obtained the images of all the participants in two separate test sessions, 7 days apart. Intraclass correlation coefficient (ICC), confidence interval, standard error of measurement, Bland-Altman plot, and Pearson correlation coefficient were used to estimate their reliability and validity. Results The ICC for the intrarater reliability of the MG muscle pennation angle measured using the DPC-BMW was > 0.916, indicating excellent reliability, and that for the interrater reliability ranged from 0.964 to 0.994. The P-US device also exhibited good reliability. A high correlation was found between the measurements of MG muscle pennation angle obtained using the DPC-BMW and that obtained using the P-US device (p < 0.01). Conclusion The DPC-BMW can provide clear images for accurate measurements, including measurements using dual probes. It has the advantage of rehabilitative US imaging for individuals who have had a stroke. More research studies are needed to evaluate the usefulness of the DPC-BMW in rehabilitation.

Download full-text PDF

Source
http://dx.doi.org/10.1080/10749357.2017.1383723DOI Listing

Publication Analysis

Top Keywords

pennation angle
20
p-us device
16
reliability validity
12
dual-probe personal
8
personal computer-based
8
computer-based muscle
8
muscle viewer
8
measuring pennation
8
angle medial
8
medial gastrocnemius
8

Similar Publications