Coronary Artery Disease: Analysis of Diagnostic Performance of CT Perfusion and MR Perfusion Imaging in Comparison with Quantitative Coronary Angiography and SPECT-Multicenter Prospective Trial.

Radiology

From the Departments of Radiology (M.R., B.K., E.Z., M.D.), Nuclear Medicine (M.P.), and Cardiology (M.L.), Charité-Universitätsmedizin Berlin, Medical School, Humboldt-Universität zu Berlin, Freie Universität Berlin, Charitéplatz 1, 10117 Berlin, Germany; Department of Health and Human Service

Published: February 2018


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose To compare the diagnostic performance of stress myocardial computed tomography (CT) perfusion with that of stress myocardial magnetic resonance (MR) perfusion imaging in the detection of coronary artery disease (CAD). Materials and Methods All patients gave written informed consent prior to inclusion in this institutional review board-approved study. This two-center substudy of the prospective Combined Noninvasive Coronary Angiography and Myocardial Perfusion Imaging Using 320-Detector Row Computed Tomography (CORE320) multicenter trial included 92 patients (mean age, 63.1 years ± 8.1 [standard deviation]; 73% male). All patients underwent perfusion CT and perfusion MR imaging with either adenosine or regadenoson stress. The predefined reference standards were combined quantitative coronary angiography (QCA) and single-photon emission CT (SPECT) or QCA alone. Results from coronary CT angiography were not included, and diagnostic performance was evaluated with the Mantel-Haenszel test stratified by disease status. Results The prevalence of CAD was 39% (36 of 92) according to QCA and SPECT and 64% (59 of 92) according to QCA alone. When compared with QCA and SPECT, per-patient diagnostic accuracy of perfusion CT and perfusion MR imaging was 63% (58 of 92) and 75% (69 of 92), respectively (P = .11); sensitivity was 92% (33 of 36) and 83% (30 of 36), respectively (P = .45); and specificity was 45% (25 of 56) and 70% (39 of 56), respectively (P < .01). When compared with QCA alone, diagnostic accuracy of CT perfusion and MR perfusion imaging was 82% (75 of 92) and 74% (68 of 92), respectively (P = .27); sensitivity was 90% (53 of 59) and 69% (41 of 59), respectively (P < .01); and specificity was 67% (22 of 33) and 82% (27 of 33), respectively (P = .27). Conclusion This multicenter study shows that the diagnostic performance of perfusion CT is similar to that of perfusion MR imaging in the detection of CAD. RSNA, 2017 Online supplemental material is available for this article.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5790301PMC
http://dx.doi.org/10.1148/radiol.2017162447DOI Listing

Publication Analysis

Top Keywords

perfusion imaging
28
perfusion perfusion
20
diagnostic performance
16
coronary angiography
16
perfusion
13
coronary artery
8
artery disease
8
performance perfusion
8
quantitative coronary
8
stress myocardial
8

Similar Publications

Acute kidney injury (AKI) is a common clinical syndrome characterized by abnormal renal function and structure. Microcirculatory perfusion disorders and inflammatory responses are critical pathophysiologies of AKI. Recently, ultrasound molecular imaging has been considered a valuable tool for preclinical and clinical diagnostics that can sensitively target histological structures of interest, particularly in evaluating renal microcirculation.

View Article and Find Full Text PDF

Objectives: On-site normothermic machine perfusion of the liver may require hepatic arterial reconstruction. The effect of arterial reconstruction on the deve-lopment of primary ischemic cholangiopathy has not been fully elucidated in liver transplants with organs donated after circulatory death. The aim of this study was to evaluate the effect of normothermic machine perfusion with arterial reconstruction at the onset of ischemic cholangiopathy in liver transplants with organs donated after circulatory death.

View Article and Find Full Text PDF

Background: The primary treatment for colorectal cancer, which is very prevalent, is surgery. Anastomotic leaking poses a significant risk following surgery. Intestinal perfusion can be objectively and instantly assessed with indocyanine green fluorescence imaging, which may lower leakage rates and enhance surgical results.

View Article and Find Full Text PDF

Myocardial Perfusion Imaging and Revascularization Predict Long-term All-cause Mortality in Patients with Suspected CAD.

Acad Radiol

September 2025

Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan (J.Y.H., C.L.K., K.L.C.); College of Medicine, National Taiwan University, Taipei, Taiwan (J.Y.H., C.K.H., K.L.C., Y.W.W.); Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan (C.K

Rationale And Objectives: The prognostic implications of myocardial perfusion imaging (MPI) are imperative to provide proper management of coronary artery disease (CAD). This study aimed to quantify the long-term prognostic value of MPI under routine clinical conditions.

Materials And Methods: This single-center retrospective cohort study evaluated all-cause mortality and cause-specific survival according to MPI findings in patients with suspected or known CAD who underwent diagnostic evaluation or assessment of myocardial ischemia and viability in a tertiary referral cardiovascular center.

View Article and Find Full Text PDF

Diagnostic reference levels (DRLs) are essential for optimizing radiologic practices and ensuring patient safety. This study aimed to establish typical DRLs for nuclear medicine (NM) procedures performed at a Brazilian public university hospital. A retrospective analysis of 2,609 patient records from 13 routine NM procedures was conducted.

View Article and Find Full Text PDF