A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Metal Artifact Reduction for Orthopedic Implants (O-MAR): Usefulness in CT Evaluation of Reverse Total Shoulder Arthroplasty. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: The objective of this study is to evaluate the effect of the metal artifact reduction algorithm for orthopedic implants (O-MAR) on CT image quality for patients with reverse total shoulder arthroplasty (RTSA), with emphasis placed on the evaluation of bone in the vicinity of prostheses.

Materials And Methods: Sixty-five patients who underwent CT scanning after RTSA were enrolled in the study. Two radiologists analyzed the images reconstructed with filtered back projection (FBP) with or without O-MAR processing. Images were evaluated to determine the degree of streaking artifacts, the confidence in depicting various structures around the prosthesis, and the presence of pseudolesions. The mean CT number and SD of the selected ROIs placed in the greater tuberosity, glenoid bone, and deltoid muscle were recorded. For measurements from the greater tuberosity and glenoid bone, the frequency with which the measurement met the typical CT number of bone was calculated.

Results: O-MAR images showed less metal streak artifact and noise and provided better visualization of the axillary neurovascular bundle compared with FBP images, with a statistically significant difference (p < 0.001 for all). FBP images were found to be statistically significantly better than O-MAR images, offering better visualization of bone cortex, bone trabeculae, and the bone-prosthesis interface (p < 0.001 for all). Scapular pseudonotching was observed on 4.6% of FBP images and 36.9% of O-MAR images. The pseudocemented appearance was noted on 47.7% of O-MAR images but was not seen on FBP images.

Conclusion: The use of O-MAR improved CT image quality for patients with RTSA in the aspect of metal artifact reduction and soft-tissue profile. However, O-MAR tends to degrade depiction of the bone trabeculae and bone cortex and generate new artifacts, including a pseudocemented appearance and scapular pseudonotching.

Download full-text PDF

Source
http://dx.doi.org/10.2214/AJR.16.17684DOI Listing