A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Implantable Doppler monitoring of buried free flaps during vascularized lymph node transfer. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background And Objectives: Reliable flap monitoring is crucial to the success of free tissue transfer, including vascularized lymph node transfer (VLNT). However, no large-scale study has examined implantable Doppler monitoring in VLNT. We aimed to determine whether an implantable Doppler system can reliably monitor flap perfusion during VLNT and also to calculate the sensitivity and specificity of this system for detecting compromise in the monitored vessel.

Methods: An analysis of prospectively collected data of patients who underwent buried VLNT with implantable Doppler monitoring between 2014 and 2015 was performed.

Results: A consecutive series of 100 patients underwent VLNT with implantable Doppler monitoring. Five cases required return to the operating room for flap exploration due to a change in Doppler signal quality. All compromised flaps were salvaged. The sensitivity of the implantable Doppler system for flap monitoring was 100%, the specificity was 97.9%, the positive predictive value was 60%, and the negative predictive value was 100%. The false-positive rate was 2%.

Conclusions: This is the largest reported series of implantable Doppler monitoring of free flap perfusion during VLNT. Our experience suggests that this is a safe and effective technique for postoperative monitoring of VLNT.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jso.24655DOI Listing