Article Abstract

A rapid and sensitive method for simultaneous screening, quantification and confirmation of 17 barbiturates in horse plasma using liquid chromatography-tandem mass spectrometry is described. Analytes were recovered from plasma by liquid-liquid extraction using methyl tert-butyl ether, separated on a C18 column, and analyzed in negative electrospray ionization mode. Multiple-reaction monitoring was employed for screening and quantification. Confirmation for the presence of the analytes was achieved by comparing ion intensity ratio. The ranges for limits of detection, quantification and confirmation were 0.003-1 ng/mL (S/N ≥ 3), 0.01-2.5 ng/mL and 0.02-5 ng/mL, respectively. The linear dynamic range of the method was 0.1-100 ng/mL. The precision and accuracy at 0.5, 5 and 50 ng/mL of all 17 barbiturates during intra-day assay were 1.6-8.6% and 96-106%, respectively. For inter-day assay, precision and accuracy at the same three concentrations were 2.6-8.9% and 96-106%, respectively. Analysis of all 17 analytes was completed within 7 min. Thus, the present method is fast, simple, sensitive and reproducibly reliable.

Download full-text PDF

Source
http://dx.doi.org/10.1093/jat/bkx025DOI Listing

Publication Analysis

Top Keywords

quantification confirmation
12
method simultaneous
8
barbiturates horse
8
horse plasma
8
screening quantification
8
precision accuracy
8
ng/ml
5
validated lc-ms-ms
4
method
4
lc-ms-ms method
4

Similar Publications

Objective: To determine optimal CT perfusion (CTP) imaging parameters for evaluating the canine prostate and to assess the diagnostic utility of CTP combined with cytopathologic evaluation and B-Raf proto-oncogene (BRAF) gene mutation testing in dogs with prostate adenocarcinoma.

Methods: For this study, 10 male dogs were enrolled, comprising 4 healthy Beagles and 6 client-owned dogs with suspected prostatic neoplasia. Computed tomography perfusion was performed in the healthy dogs using varied contrast agent doses and injection durations.

View Article and Find Full Text PDF

Microbial co-cultures provide significant advantages over commonly used axenic cultures in biotechnological processes, including increased productivity and access to novel natural products. However, differentiated quantification of the microorganisms in co-cultures remains challenging using conventional measurement techniques. To address this, a fluorescence-based approach was developed to enable the differentiated online monitoring of microbial growth in co-cultures.

View Article and Find Full Text PDF

Human Health Risk Assessment of Fluoride Intake from Tea and Herbal Infusion (Loose-Leaf and Bagged) Consumption in Brazil.

Biol Trace Elem Res

September 2025

Laboratório de Testes Farmacológicos E Toxicológicos - LEFT, Universidade Federal Do Rio Grande, Instituto de Ciências Biológicas, Av. Itália Km 8 Bairro Carreiros, CEP 96203-900, Rio Grande, Rio Grande Do Sul, Brasil.

This study aimed to evaluate fluoride concentrations in a variety of commonly consumed teas and Herbal infusions in Brazil and assess potential Health risks associated with their ingestion. A total of 21 samples were analyzed, including 12 loose-leaf and 9 commercially bagged products. Fluoride quantification was performed using a validated spectrophotometric method, and a deterministic and probabilistic human Health risk assessment was conducted.

View Article and Find Full Text PDF

Objectives: The escalating global incidence of obesity, cardiometabolic disease and sarcopenia necessitates reliable body composition measurement tools. MRI-based assessment is the gold standard, with utility in both clinical and drug trial settings. This study aims to validate a new automated volumetric MRI method by comparing with manual ground truth, prior volumetric measurements, and against a new method for semi-automated single-slice area measurements.

View Article and Find Full Text PDF

Myocardial fibrosis, a key pathological feature of hypertensive heart disease (HHD), remains diagnostically challenging due to limited clinical tools. In this study, a FAPI-targeted uptake mechanism previously reported by our group, originally developed for tumor imaging, is extended to the detection of myocardial fibrosis in HHD using [F]F-NOTA-FAPI-MB. The diagnostic performance of this tracer is compared with those of [F]F-FDG, [F]F-FAPI-42, and [F]F-NOTA-FAP2286, and its potential for fluorescence imaging is also evaluated.

View Article and Find Full Text PDF